Measuring The Acoustical Properties of Fluids and Solid Materials Via Dealing With A-SCAN (GAMPT) Ultrasonic
Open Access
- 1 August 2018
- conference paper
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1083 (1) , 012053
Abstract
This article displays a general overview about the measurements of acoustical properties (speed of sound and attenuation) for both the fluids and solid materials via dealing with A-scan or A-mode GAMPT mbH ultrasound technique (ultrasound transmission and reception). In addition, measuring the thickness of protective layer of the probe and its influence on the speed of sound and attenuation of fluids and solids materials by applying the Pulse Echo ultrasound speed method and its formula. However, this method used to measure the distilled water and Doppler dummy fluid as a liquid items and acrylic plate with different sizes as solid materials. The outcomes resulted from the study were the speed of sound and attenuation measurements of both the fluids and solid materials via dealing with A-scan GAMPT mbH ultrasound technique were suitable. Furthermore, the protective layer thickness of the probe was influenced on the speed of sound measurements. So, we can remove the influence of inaccuracy by knowing the protective layer thickness and this way can increase the precise in ultrasonic speed.Keywords
This publication has 9 references indexed in Scilit:
- Fabrication of Two Flow Phantoms for Doppler Ultrasound ImagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2016
- Wall-less Flow Phantom for High-Frequency Ultrasound ApplicationsUltrasound in Medicine & Biology, 2015
- A comparison of methods for the determination of sound velocity in biological materials: A case studyUltrasonics, 2013
- An ideal blood mimicking fluid for doppler ultrasound phantomsJournal of Medical Physics, 2006
- Ultrasonic assessment of tissue hydration statusUltrasonics, 2005
- Validation of a sensitivity performance index test protocol and evaluation of colour Doppler sensitivity for a range of ultrasound scannersUltrasound in Medicine & Biology, 2004
- Validation of a New Blood-Mimicking Fluid for Use in Doppler Flow Test ObjectsUltrasound in Medicine & Biology, 1998
- Development of an example flow test object and comparison of five of these test objects, constructed in various laboratoriesUltrasonics, 1998
- Performance tests of Doppler ultrasound equipment with a tissue and blood-mimicking phantom.Journal of Ultrasound in Medicine, 1988