Patient-Specific Haemodynamic Analysis of Virtual Grafting Strategies in Type-B Aortic Dissection: Impact of Compliance Mismatch
Open Access
- 4 March 2024
- journal article
- research article
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 15 (3) , 290-304
Abstract
Introduction: Compliance mismatch between the aortic wall and Dacron Grafts is a clinical problem concerning aortic haemodynamics and morphological degeneration. The aortic stiffness introduced by grafts can lead to an increased left ventricular (LV) afterload. This study quantifies the impact of compliance mismatch by virtually testing different Type-B aortic dissection (TBAD) surgical grafting strategies in patient-specific, compliant computational fluid dynamics (CFD) simulations. Materials and Methods: A post-operative case of TBAD was segmented from computed tomography angiography data. Three virtual surgeries were generated using different grafts; two additional cases with compliant grafts were assessed. Compliant CFD simulations were performed using a patient-specific inlet flow rate and three-element Windkessel outlet boundary conditions informed by 2D-Flow MRI data. The wall compliance was calibrated using Cine-MRI images. Pressure, wall shear stress (WSS) indices and energy loss (EL) were computed. Results: Increased aortic stiffness and longer grafts increased aortic pressure and EL. Implementing a compliant graft matching the aortic compliance of the patient reduced the pulse pressure by 11% and EL by 4%. The endothelial cell activation potential (ECAP) differed the most within the aneurysm, where the maximum percentage difference between the reference case and the mid (MDA) and complete (CDA) descending aorta replacements increased by 16% and 20%, respectively. Conclusion: This study suggests that by minimising graft length and matching its compliance to the native aorta whilst aligning with surgical requirements, the risk of LV hypertrophy may be reduced. This provides evidence that compliance-matching grafts may enhance patient outcomes.Keywords
All Related Versions
Funding Information
- British Heart Foundation (NH/20/1/34705)
- Wellcome / EPSRC Centre for Interventional and Surgical Sciences (NS/A000050/1)
This publication has 82 references indexed in Scilit:
- Computational study of fenestration and parallel grafts used in TEVAR of aortic arch aneurysmsInternational Journal for Numerical Methods in Biomedical Engineering, 2022
- The influence of inlet velocity profile on predicted flow in type B aortic dissectionBiomechanics and Modeling in Mechanobiology, 2020
- Influence of Shear‐Thinning Rheology on the Mixing Dynamics in Taylor‐Couette FlowChemical Engineering & Technology, 2019
- A comparison of hemodynamic metrics and intraluminal thrombus burden in a common iliac artery aneurysmInternational Journal for Numerical Methods in Biomedical Engineering, 2016
- Blood linear viscoelasticity by small amplitude oscillatory flowRheologica Acta, 2015
- On the Use of In Vivo Measured Flow Rates as Boundary Conditions for Image-Based Hemodynamic Models of the Human Aorta: Implications for Indicators of Abnormal FlowAnnals of Biomedical Engineering, 2011
- Development of a compliant and cytocompatible micro‐fibrous polyethylene terephthalate vascular scaffoldJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2011
- Computational Hemodynamic Analysis in Congenital Heart Disease: Simulation of the Norwood ProcedureAnnals of Biomedical Engineering, 2010
- The onset of turbulence in physiological pulsatile flow in a straight tubeExperiments in Fluids, 1998
- Abdominal aorta: characterisation of blood flow and measurement of its regional distribution by cine magnetic resonance phase-shift velocity mappingEuropean Radiology, 1992