Digital radiography of the gastrointestinal tract
Authors:
- 1 December 1988
- journal article
- research article
- Published by Springer Nature in Gastrointestinal Radiology
- Vol. 13 (1) , 191-196
Abstract
The gastrointestinal tract lends itself quite well to digital imaging. Since fluoroscopy is already employed, the images can easily be obtained in digital format and several manufacturers have now developed systems for commercial use. Because of the type of pathology as well as the inherent subject contrast, it would appear the resolution requirements for digital imaging of the gastrointestinal tract are less than in other organ systems. The necessary resolution level is already technically available and feasible without significant cost. Digital imaging also holds promise of at least a modest reduction in radiation dose to the patient, as well as a reduction in costs, although these factors are operator dependent. However, digital imaging provides a latitude in performing the examination that is not available with screenfilm systems. Finally, there is promise that by acquiring gastrointestinal images in digital format, manipulation of the images may help increase diagnostic accuracy by improving both technical and perceptive components of diagnosis. Not only will simple image manipulation be helpful but there is even potential for computer-assisted evaluation of gastrointestinal images.Keywords
This publication has 13 references indexed in Scilit:
- Digital gastrointestinal imaging: the effect of pixel size on detection of subtle mucosal abnormalities.Radiology, 1987
- Digital radiography of subtle pulmonary abnormalities: an ROC study of the effect of pixel size on observer performance.Radiology, 1986
- Clinical Application Of High Resolution Digital Image Storage For General Radiography1985
- Videofluorography and pulsed fluoroscopy using a 512 X 512-pixel digital image system.Radiology, 1985
- Noise analysis of a digital radiography systemAmerican Journal of Roentgenology, 1984
- Patient exposure requirements for high contrast resolution in digital radiographic systemsAmerican Journal of Roentgenology, 1984
- Clinical experience with combined videofluorography and pulsed fluoroscopy.Radiology, 1982
- The cost of managing digital diagnostic images.Radiology, 1982
- The effect of varying spatial resolution on the detectability of diffuse pulmonary nodules. Assessment with digitized conventional radiographs.Radiology, 1981
- Colorectal carcinoma missed on double contrast barium enema study: a problem in perceptionAmerican Journal of Roentgenology, 1981