Automated Multi-Wavelength Quality Assessment of Photoplethysmography Signals Using Modulation Spectrum Shape Features
Open Access
Abstract
Photoplethysmography (PPG) is used to measure blood volume changes in the microvascular bed of tissue. Information about these changes along time can be used for estimation of various physiological parameters, such as heart rate variability, arterial stiffness, and blood pressure, to name a few. As a result, PPG has become a popular biological modality and is widely used in wearable health devices. However, accurate measurement of various physiological parameters requires good-quality PPG signals. Therefore, various signal quality indexes (SQIs) for PPG signals have been proposed. These metrics have usually been based on statistical, frequency, and/or template analyses. The modulation spectrogram representation, however, captures the second-order periodicities of a signal and has been shown to provide useful quality cues for electrocardiograms and speech signals. In this work, we propose a new PPG quality metric based on properties of the modulation spectrum. The proposed metric is tested using data collected from subjects while they performed various activity tasks contaminating the PPG signals. Experiments on this multi-wavelength PPG dataset show the combination of proposed and benchmark measures significantly outperforming several benchmark SQIs with improvements of 21.3% BACC (balanced accuracy) for green, 21.6% BACC for red, and 19.0% BACC for infrared wavelengths, respectively, for PPG quality detection tasks. The proposed metrics also generalize for cross-wavelength PPG quality detection tasks.Keywords
Funding Information
- Mitacs
This publication has 38 references indexed in Scilit:
- A Robust Heart Rate Monitoring Scheme Using Photoplethysmographic Signals Corrupted by Intense Motion ArtifactsIEEE Transactions on Biomedical Engineering, 2015
- A new look at the essence of the imaging photoplethysmographyScientific Reports, 2015
- A combined segmenting and non-segmenting approach to signal quality estimation for ambulatory photoplethysmographyPhysiological Measurement, 2014
- TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical ExerciseIEEE Transactions on Biomedical Engineering, 2014
- MS-QI: A Modulation Spectrum-Based ECG Quality Index for Telehealth ApplicationsIEEE Transactions on Biomedical Engineering, 2014
- Dynamic time warping and machine learning for signal quality assessment of pulsatile signalsPhysiological Measurement, 2012
- Statistical approach for the detection of motion/noise artifacts in Photoplethysmogram2011
- Signal quality measures for pulse oximetry through waveform morphology analysisPhysiological Measurement, 2011
- Index of Balanced Accuracy: A Performance Measure for Skewed Class Distributions2009
- Photoplethysmography and its application in clinical physiological measurementPhysiological Measurement, 2007