Heat Transfer in a Rotating Twin-Pass Trapezoidal-Sectioned Passage Roughened by Skewed Ribs on Two Opposite Walls
Authors:
- 1 December 2006
- journal article
- research article
- Published by Taylor & Francis in Heat Transfer Engineering
- Vol. 27 (10) , 63-79
Abstract
An experimental study of heat transfer in a radially rotating twin-pass trapezoidal-sectioned duct with two opposite walls roughened by 45° staggered ribs was performed. Two channel orientations of 0° and 45° from the direction of rotation were tested. At each Reynolds number of 5000, 7500, 10000, 12500, and 15000, local Nusselt numbers along the centerlines of two rib-roughened surfaces with five different heating levels were acquired at rotating numbers of 0, 0.1, 0.3, 0.5, 0.7, and 1. A selection of experimental results illustrates the isolated and interactive influences of convective inertial, Coriolis, and rotating buoyancy forces on local and centerline-averaged heat transfers. The isolated Coriolis force-effect improves heat transfer over two unstable surfaces of the rotating twin-pass channel. The rotating buoyancy effect undermines local heat transfer, but its influence is alleviated when the rotating number increases. At rotating number of 0.7 and 1, the rotating buoyancy force acting with counter-flow manner considerably impairs local heat transfer in the end-region of the first passage with radially outward flow. With the rotating numbers in the range of 0.1 to 1, the heat transfer differences between the two channels with orientations of 0° and 45° are in the range of 5–26%. As a strategic aim of the present study, heat transfer correlations are derived to evaluate the centerline-averaged Nusselt numbers over two rib-roughened surfaces that permit the individual and interactive influences of convective inertia, Coriolis force, and rotating buoyancy to be quantified. As the full-field spatial heat transfer variations in the present rotating channel are not measured, the local heat transfer results generated by the present study are limited to the locations measured.Keywords
This publication has 18 references indexed in Scilit:
- Heat transfer in a radially rotating square duct fitted with in-line transverse ribsInternational Journal of Thermal Sciences, 2003
- Heat (Mass) Transfer in a Diagonally Oriented Rotating Two-Pass Channel With Rib-Roughened WallsJournal of Heat Transfer, 1999
- An experimental study of heat transfer in a simulated turbine blade cooling passageInternational Journal of Heat and Mass Transfer, 1998
- Local Heat Transfer in Rotating Smooth and Ribbed Two-Pass Square Channels With Three Channel OrientationsJournal of Heat Transfer, 1996
- Effect of model orientation and wall heating condition on local heat transfer in a rotating two-pass square channel with rib turbulatorsInternational Journal of Heat and Mass Transfer, 1995
- Heat Transfer in Rotating Serpentine Passages With Trips Skewed to the FlowJournal of Turbomachinery, 1994
- Uneven Wall Temperature Effect on Local Heat Transfer in a Rotating Two-Pass Square Channel With Smooth WallsJournal of Heat Transfer, 1993
- Heat Transfer in Rotating Serpentine Passages With Trips Normal to the FlowJournal of Turbomachinery, 1992
- The Influence of Rotation on the Heat Transfer Characteristics of Circular, Triangular, and Square-Sectioned Coolant Passages of Gas Turbine Rotor BladesJournal of Turbomachinery, 1988
- An Experimental Study of Local and Mean Heat Transfer in a Triangular-Sectioned Duct Rotating in the Orthogonal ModeJournal of Engineering for Gas Turbines and Power, 1984