Capillary Vibrating Sharp-Edge Spray Ionization (cVSSI) for Voltage-Free Liquid Chromatography-Mass Spectrometry
- 21 February 2019
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 30 (5) , 824-831
Abstract
Here, we report a continuous flow-based ionization method, capillary vibrating sharp-edge spray ionization (cVSSI), that nebulizes liquid sample directly at the outlet of a capillary without using high-speed nebulization gas or a high electrical field. cVSSI is built upon the recently reported VSSI principle which nebulizes bulk liquid using vibrating sharp-edges. By attaching a short piece of fused silica capillary on top of the vibrating glass slide in VSSI, liquid is nebulized at the outlet of the capillary as the result of the vibration. Utilizing standard 360-μm OD/100-μm ID capillary, cVSSI works with a wide range of flow rates from 1 μL/min to 1 mL/min. The power consumption is as low as 130 mW. ESI-like MS spectra are obtained for small molecules, peptides, and proteins. Five orders of magnitude linear response for acetaminophen solution is achieved with a limit of detection (LOD) of 3 nM. cVSSI is also demonstrated to be compatible with LC-MS analysis. Two LC-MS applications are demonstrated with cVSSI: (1) separation and detection of a mixture of small molecules and (2) bottom-up proteomics using a protein digest. A mixture of nine common metabolites was appropriately separated and detected using LC-cVSSI-MS. In the bottom-up experiment, 78 peptides were detected using LC-cVSSI-MS/MS with a protein coverage of 100% for cytochrome c, which is comparable with the coverage obtained using LC-ESI-MS. cVSSI offers a means of interfacing LC or other continuous flow-based applications to mass spectrometers with the salient features of voltage-free, flexibility, small footprint, and low power consumption.Keywords
Funding Information
- West Virginia University (Start-up)
- Don and Linda Brodie Resource Fund for Innovation
- Division of Chemistry (CHE-1553021)
- National Institute of General Medical Sciences (R01GM114494)
This publication has 35 references indexed in Scilit:
- Forensic analysis of inks by imaging desorption electrospray ionization (DESI) mass spectrometryThe Analyst, 2007
- LC-MS Development Strategies for Quantitative BioanalysisCurrent Drug Metabolism, 2006
- Gas chromatography mass spectrometry–based metabolite profiling in plantsNature Protocols, 2006
- Forensic applications of isotope ratio mass spectrometry—A reviewForensic Science International, 2006
- Ambient mass spectrometry using desorption electrospray ionization (DESI): instrumentation, mechanisms and applications in forensics, chemistry, and biologyJournal of Mass Spectrometry, 2005
- Quantitative analysis of cytokinins in plants by liquid chromatography–single-quadrupole mass spectrometryAnalytica Chimica Acta, 2003
- Quantitative high‐throughput analysis of drugs in biological matrices by mass spectrometryMass Spectrometry Reviews, 2003
- Liquid chromatography–mass spectrometry in forensic and clinical toxicologyJournal of Chromatography B: Biomedical Sciences and Applications, 1998
- Separation of osmium from geological materials by solvent extraction for analysis by thermal ionisation mass spectrometryAnalytica Chimica Acta, 1996
- Melatonin in edible plants identified by radioimmunoassay and by high performance liquid chromatography‐mass spectrometryJournal of Pineal Research, 1995