Abstract
Technical note, case report. and review of literature. Description of anterior transarticular internal fixation for traumatic C1-C2 instability. The currently effective posterior approaches for instrumentation of the C1-C2 junction require considerable soft tissue dissection and prone patient positioning. Some medical and anatomic conditions restrict the posterior approach. An odontoid screw and anterior transarticular C1-C2 screws were used to instrument an unstable injury at this junction. The lesion consisted of a type II dens fracture and C1 ring disruption. Two high-quality fluoroscopy machines, a radiolucent OSI fracture table, and the Synframe (Synthes, Paoli, PA) retraction system are used for this procedure. The implant of choice is the 4.0-mm cannulated titanium screw. At 4-month follow-up, successful stabilization without failure of hardware is documented. The patient's neurologic status is stable, with a minor residual left upper extremity motor deficit. The patient has restricted C-spine rotation but no neck pain with movement. Anterior stabilization through a standard Smith-Robinson approach of the C1-C2 junction with screws into the odontoid and the lateral masses of C1 is effective. Supine positioning and minimal soft tissue dissection are advantages of this method over standard posterior transarticular instrumentation. Knowledge of the local anatomy, strict adherence to the operative protocol, and high-quality fluoroscopy avoid potential surgical complications.Keywords
This publication has 12 references indexed in Scilit:
- Posterior C1–C2 Fusion With Polyaxial Screw and Rod FixationSpine, 2001
- Biomechanical testing of the anterior atlantoaxial locking plateDer Orthopäde, 2001
- Biomechanical Comparison of Five Different Atlantoaxial Posterior Fixation TechniquesSpine, 2000
- C1—C2 Intra-articular Screw Fixation for Atlantoaxial Posterior StabilizationSpine, 2000
- Modified Gallie Technique Versus Transarticular Screw Fixation in C1-C2 FusionClinical Orthopaedics and Related Research, 1999
- Plate and screw fixation for atlanto-axial subluxationActa Neurochirurgica, 1994
- Atlanto-Axial Stabilization with Posterior Transarticular Screw FixationNeurosurgery, 1993
- Post-traumatic ligamentous instability of the atlantoaxial joint: a comparison between the Gallie and Brooks fusionsInjury, 1993
- Primary Posterior Fusion C1/2 in Odontoid FracturesJournal of Spinal Disorders, 1992
- Biomechanical Evaluation of Four Different Posterior Atlantoaxial Fixation TechniquesSpine, 1992