The Effect of Plate Rotation on the Stiffness of Femoral LISS: A Mechanical Study
Authors:
- Afshin KhalafiAKAfshin Khalafi
- Shane CurtissSCShane Curtiss
- Ra Scott HazelwoodRHRa Scott Hazelwood
- Philip WolinskyPWPhilip Wolinsky
- 1 September 2006
- journal article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 20 (8) , 542-546
Abstract
Malposition of the femoral Less Invasive Stabilization System (LISS) plate may alter its biomechanical behavior. This study compares the mechanical stability of "correctly" affixed LISS plates matching the slope of the lateral femoral condyle to "incorrectly" placed LISS plates fixed in external rotation relative to the distal femur. A fracture gap model was created to simulate a comminuted supracondylar femur fracture (AO/OTA33-A3). Fixation was achieved using two different plate positions: the LISS plate was either placed "correctly" by internally rotating the plate to match the slope of the lateral femoral condyle, or "incorrectly" by externally rotating the plate relative to the distal femur. Following fixation, the constructs were loaded in axial, torsional, and cyclical axial modes in a material testing machine. Stiffness in axial and torsional loading; total deformation and irreversible (plastic) deformation in cyclical axial loading. The mean axial stiffness for the correctly placed LISS constructs was 21.5% greater than the externally rotated LISS constructs (62.7 N/mm vs. 49.3 N/mm; P = 0.0007). No significant difference was found in torsional stiffness between the two groups. Cyclical axial loading caused significantly less (P < 0.0001) plastic deformation in the correct group (0.6 mm) compared with externally rotated group (1.3 mm). All the constructs in the incorrect group failed, where failure was defined as a complete closure of the medial fracture gap, prior to completion of the test cycles. Correct positioning of the LISS plate for fixation of distal femur fractures results in improved mechanical stability as reflected by an increased stiffness in axial loading and decreased plastic deformation at the bone-screw interface.Keywords
This publication has 20 references indexed in Scilit:
- Use of the Less Invasive Stabilization System (LISS) in patients with distal femoral (AO33) fractures: a prospective multicenter studyArchives of orthopaedic and trauma surgery, 2005
- Early Results of the Less Invasive Stabilization System for Mechanically Unstable Fractures of the Distal Femur (AO/OTA Types A2, A3, C2, and C3)Journal of Orthopaedic Trauma, 2004
- Treatment of Distal Femur Fractures Using the Less Invasive Stabilization SystemJournal of Orthopaedic Trauma, 2004
- Distal femoral fractures: long-term outcome following stabilisation with the LISSInjury, 2004
- Evolution of Minimally Invasive Plate Osteosynthesis (MIPO) in the femurInjury, 2001
- The development of the distal femur Less Invasive Stabilization System (LISS)Injury, 2001
- Distal femoral fracture fixation utilizing the Less Invasive Stabilization System (L.I.S.S.): The technique and early resultsInjury, 2001
- Minimally invasive fracture stabilization of distal femoral fractures with the LISS: A prospective multicenter study results of a clinical study with special emphasis on difficult casesInjury, 2001
- Distal femoral fractures and LISS stabilizationInjury, 2001
- Fixation of distal femoral fractures above total knee arthroplasty utilizing the Less Invasive Stabilization System (L.I.S.S.)Injury, 2001