Analysis of left main coronary artery bifurcation lesions treated with biolimus‐eluting DEVAX AXXESS plus nitinol self‐expanding stent: Intravascular ultrasound results of the AXXENT trial
Authors:
- 16 December 2008
- journal article
- clinical trial
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 73 (1) , 34-41
Abstract
Objective: To assess the efficacy of the AXXESS stent on the treatment of left main coronary artery (LMCA) bifurcation lesions using IVUS. Background: The treatment of LMCA bifurcation lesions remains challenging even with the use of drug‐eluting stents. The AXXESS system is a biolimus A9‐eluting self‐expanding stent, dedicated to the treatment of bifurcation lesions. Methods: Data were obtained from the AXXENT trial, a prospective, single‐arm, multicenter study designed to evaluate the efficacy of the AXXESS stent on the treatment of LMCA bifurcation lesions. IVUS was available in 26 cases at 6‐months follow‐up. Volumetric and cross‐sectional analyses within the AXXESS stent, and cross‐sectional analyses at the ostia of left anterior descending (LAD) and left circumflex coronary arteries (LCX) were performed. Results: Within the AXXESS stent, percent neointimal volume obstruction was (3.0 ± 4.1)% with a minimal lumen area of 10.3 ± 2.6 mm2. AXXESS stent volume showed an 12.4% increase at follow‐up compared with postprocedure (P = 0.04). Lumen area was significantly smaller in the LCX ostium compared with the LAD ostium at follow‐up (3.6 ± 1.3 mm2 vs. 5.5 ± 2.0 mm2, P = 0.0112). There was greater neointimal formation in the LCX ostium compared with the LAD ostium (1.37 ± 1.20 mm2 vs. 0.30 ± 0.36 mm2, P = 0.0003). Conclusions: The AXXESS stent in the LMCA showed enlargement through 6‐months follow‐up and significant neointimal suppression. Greater neointimal formation and relatively inadequate stent expansion may contribute to luminal narrowing in the LCX ostium.Keywords
This publication has 24 references indexed in Scilit:
- Analysis of bifurcation lesions treated with novel drug‐eluting dedicated bifurcation stent system: Intravascular ultrasound results of the AXXESS PLUS trialCatheterization and Cardiovascular Interventions, 2007
- Six-Month Clinical and Angiographic Results of a Dedicated Drug-Eluting Stent for the Treatment of Coronary Bifurcation NarrowingsThe American Journal of Cardiology, 2007
- Comparison of Simple and Complex Stenting Techniques in the Treatment of Unprotected Left Main Coronary Artery Bifurcation StenosisThe American Journal of Cardiology, 2006
- Distal Left Main Coronary Disease Is a Major Predictor of Outcome in Patients Undergoing Percutaneous Intervention in the Drug-Eluting Stent EraJACC, 2006
- Serial Angiographic Follow-Up of Sirolimus-Eluting Stents for Unprotected Left Main Coronary Artery RevascularizationJACC, 2006
- Late Incomplete Stent Apposition After Sirolimus-Eluting Stent ImplantationJACC, 2005
- Early and Mid-Term Results of Drug-Eluting Stent Implantation in Unprotected Left MainCirculation, 2005
- Delivered Dose and Vascular Response After β-Radiation for In-Stent RestenosisCirculation, 2002
- American College of Cardiology clinical expert consensus document on standards for acquisition, measurement and reporting of intravascular ultrasound studies (ivus)31When citing this document, the American College of Cardiology would appreciate the following citation format: Mintz GS, Nissen SE, Anderson WD, Bailey SR, Erbel R, Fitzgerald PJ, Pinto FJ, Rosenfield K, Siegel RJ, Tuzcu EM, Yock PG. ACC Clinical Expert Consensus Document on Standards for the acquisition, measurement and reporting of intravascular ultrasound studies: a report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents (Committee to Develop a Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies [IVUS]). J Am Coll Cardiol2001;37:1478–92.33Address for reprints: This document is available on the ACC Website at www.acc.org. Reprints of this document are available for $5.00 each by calling 800-253-4636 (U.S. only) or writing to the Resource Center, American College of Cardiology, Educational Services, 9111 Old Georgetown Road, Bethesda, MD 20814-1699.JACC, 2001
- Angiographic Follow-up after Placement of a Self-Expanding Coronary-Artery StentNew England Journal of Medicine, 1991