Effect of Overnight Wear Orthokeratology Lenses on Corneal Shape and Tears
Authors:
- Ping DongPDPing Dong
- Hu LiuHLHu Liu
- 1 September 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 44 (5) , 304-307
Abstract
Objective: The aim of this study was to explore the effects of the overnight wear orthokeratology (OK) lenses on corneal shape and tear film stability. Methods: Forty patients with myopia aged between 11 and 18 years who wore OK lens continuously for more than 1 year were selected. Refractive error (D), corneal curvature, corneal surface regularity index (SRI), tear breakup time (TBUT), Schirmer I test score, and corneal staining were measured at the following time points: 1 week before wearing the OK lens (T0) and 1 week (T1), 1 month (T2), 3 months (T3), 6 months (T4), and 12 months (T5) after wear. Results: Compared with T0, the average spherical refractions at other time points had become less myopic, flattens the central cornea, the SRI increased, and the TBUT decreased (PP<0.05). Conclusions: The overnight wear OK lenses may have decreased the degree of myopia and flattened the cornea while leaving basal tear secretion unaffected; however, the stability of tears decreased, therefore regular follow-ups are recommended.Keywords
This publication has 23 references indexed in Scilit:
- Myopia Control during Orthokeratology Lens Wear in Children Using a Novel Study DesignOphthalmology, 2015
- Myopia Control in Children through Refractive Therapy Gas Permeable Contact Lenses: Is it for Real?American Journal of Ophthalmology, 2013
- Corneal Reshaping Influences Myopic Prescription Stability (CRIMPS)Eye & Contact Lens: Science & Clinical Practice, 2013
- Retardation of Myopia in Orthokeratology (ROMIO) Study: A 2-Year Randomized Clinical TrialInvestigative Ophthalmology & Visual Science, 2012
- Changes in Corneal Biometry and the Associated Histology in Rhesus Monkeys Wearing Orthokeratology Contact LensesCornea, 2012
- Changes in Diadenosine Polyphosphates during Alignment-Fit and Orthokeratology Rigid Gas Permeable Lens WearInvestigative Ophthalmology & Visual Science, 2012
- Changes in the Anterior and Posterior Radii of the Corneal Curvature and Anterior Chamber Depth by OrthokeratologyEye & Contact Lens: Science & Clinical Practice, 2008
- Orthokeratology review and updateClinical and Experimental Optometry, 2006
- Orthokeratology (Corneal Refractive Therapy)Eye & Contact Lens: Science & Clinical Practice, 2004
- Clinical study of orthokeratology in young myopic adolescentsInternational Contact Lens Clinic, 1999