On the Failure of a Gas Foil Bearing: High Temperature Operation Without Cooling Flow
- 17 September 2013
- journal article
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 135 (11) , 112506
Abstract
Implementing gas foil bearings (GFBs) in micro gas turbine engines is a proven approach to improve system efficiency and reliability. Adequate thermal management for operation at high temperatures, such as in a gas turbine or a turbocharger, is important to control thermal growth of components and to remove efficiently mechanical energy from the rotor mainly. The paper presents a test rotor supported on GFBs operating with a heated shaft and reports components temperatures and shaft motions at an operating speed of 37 krpm. An electric cartridge heater loosely inserted in the hollow rotor warms the test system. Thermocouples and noncontact infrared thermometers record temperatures on the bearing sleeve and rotor outer diameter (OD), respectively. No forced cooling air flow streams were supplied to the bearings and rotor, in spite of the high temperature induced by the heater on the shaft outer surface. With the rotor spinning, the tests consisted of heating the rotor to a set temperature, recording the system component temperatures until reaching thermal equilibrium in ∼ 60 min, and stepping the heater set temperature by 200 °C. The experiments proceeded without incident until the heater set temperature equaled 600 °C. Ten minutes into the test, noise became apparent and the rotor stopped abruptly. The unusual operating condition, without cooling flow and a too large increment in rotor temperature, reaching 250 °C, led to the incident which destroyed one of the foil bearings. Post-test inspection evidenced seizure of the hottest bearing (closest to the heater) with melting of the top foil at the locations where it rests on the underspring crests (bumps). Analysis reveals a notable reduction in bearing clearance as the rotor temperature increases until seizure occurs. Upon contact between the rotor and top foil, dry-friction quickly generated vast amounts of energy that melted the protective coating and metal top foil. Rather than a reliability issue with the foil bearings, the experimental results show poor operating procedure and ignorance on the system behavior (predictions). A cautionary tale and a lesson in humility follow.Keywords
This publication has 12 references indexed in Scilit:
- Effect of Cooling Flow on the Operation of a HotRotor-Gas Foil Bearing SystemJournal of Engineering for Gas Turbines and Power, 2012
- Thermal Management and Rotordynamic Performance of a Hot Rotor-Gas Foil Bearings System—Part II: Predictions Versus Test DataJournal of Engineering for Gas Turbines and Power, 2011
- Thermal Management and Rotordynamic Performance of a Hot Rotor-Gas Foil Bearings System—Part I: MeasurementsJournal of Engineering for Gas Turbines and Power, 2011
- Identification of Structural Stiffness and Energy Dissipation Parameters in a Second Generation Foil Bearing: Effect of Shaft TemperatureJournal of Engineering for Gas Turbines and Power, 2010
- Thermohydrodynamic Analysis of Bump Type Gas Foil Bearings: A Model Anchored to Test DataJournal of Engineering for Gas Turbines and Power, 2010
- Thermohydrodynamic Model Predictions and Performance Measurements of Bump-Type Foil Bearing for Oil-Free Turboshaft Engines in Rotorcraft Propulsion SystemsJournal of Tribology, 2009
- Thermal Management Techniques for Oil-Free Turbomachinery SystemsTribology Transactions, 2007
- Low-friction wear-resistant coatings for high-temperature foil bearingsTribology International, 2005
- An Experimental Investigation into the Temperature Profile of a Compliant Foil Air BearingTribology Transactions, 2004
- Load Capacity Estimation of Foil Air Journal Bearings for Oil-Free Turbomachinery ApplicationsTribology Transactions, 2000