Automatic Radiobiological Comparison of Radiation Therapy Plans: An Application to Gastric Cancer
Open Access
Abstract
(1) Aim: This study was conducted to radiobiologically compare radiotherapy plans for gastric cancer with a newly developed software tool. (2) Methods: Treatment planning was performed on two computational phantoms simulating adult male and female patients. Three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans for gastric cancer were generated with three-photon beam energies. The equivalent uniform dose (EUD), tumor control probability (TCP) of the target and normal tissue control probability (NTCP) of eight different critical organs were calculated. A new software was employed for these calculations using the EUD-based model and dose-volume-histogram data. (3) Results: The IMRT and VMAT plan led to TCPs of 51.3–51.5%, whereas 3D-CRT gave values up to 50.2%. The intensity-modulated techniques resulted in NTCPs of (5.3 × 10−6–3.3 × 10−1)%. The corresponding NTCPs from 3D-CRT were (3.4 × 10−7–7.4 × 10−1)%. The above biological indices were automatically calculated in less than 40 s with the software. (4) Conclusions: The direct and quick radiobiological evaluation of radiotherapy plans is feasible using the new software tool. The IMRT and VMAT reduced the probability of the appearance of late effects in most of the surrounding critical organs and slightly increased the TCP compared to 3D-CRT.Keywords
This publication has 29 references indexed in Scilit:
- The use and QA of biologically related models for treatment planning: Short report of the TG-166 of the therapy physics committee of the AAPMMedical Physics, 2012
- 4D XCAT phantom for multimodality imaging researchMedical Physics, 2010
- Interobserver Variation of Clinical Target Volume Delineation in Gastric CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Can All Centers Plan Intensity-Modulated Radiotherapy (IMRT) Effectively? An External Audit of Dosimetric Comparisons Between Three-Dimensional Conformal Radiotherapy and IMRT for Adjuvant Chemoradiation for Gastric CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- A free program for calculating EUD-based NTCP and TCP in external beam radiotherapyPhysica Medica, 2007
- Analytical approach to estimate normal tissue complication probability using best fit of normal tissue tolerance doses into the NTCP equation of the linear quadratic model.Journal of Cancer Research and Therapeutics, 2005
- Basic anatomical and physiological data for use in radiological protection: reference valuesAnnals of the ICRP, 2002
- Chemoradiotherapy after Surgery Compared with Surgery Alone for Adenocarcinoma of the Stomach or Gastroesophageal JunctionThe New England journal of medicine, 2001
- Reporting and analyzing dose distributions: A concept of equivalent uniform doseMedical Physics, 1997
- Radiation dose-response of human tumorsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1995