A Low-Power On-Chip ECG Monitoring System Based on MWCNT/PDMS Dry Electrodes
- 10 June 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (21) , 12799-12806
Abstract
Wearable technologies have established novel strategies for continuous electrocardiogram (ECG) monitoring, exploiting recent developments in sensors and integrated circuit technology. Advances in dry electrodes fabrication improved the growth of wearable devices. Herein, we present an on-chip integrated ECG signal acquisition system along with dry electrodes for wearable and long-term monitoring. Custom electrodes are fabricated using multi-walled carbon nanotube (MWCNT) and Polydimethylsiloxane (PDMS) composite on a flexible substrate. A1.5 μW fully-differential operational transconductance amplifier (OTA) with a capacitive-resistive feedback network is designed in 130 nm CMOS process achieving a mid-band gain of 43.09 dB and an input-referred noise of 2.81 μVrms in the range from 0.175 Hz to 1.636 kHz. Reconfigurability of the lower cut-off frequency is achieved by controlling the bias voltage of the triple-well nMOS transistors acting as the feedback pseudoresistor. Electrodes with different surface area and MWCNT concentrations were investigated in a real-time ECG measurement scenario. The recorded signals achieve a high signal-to-noise ratio which spans from 35.7 dB to 38.6 dB with the increasing MWCNT concentration. Experimental results demonstrate that the proposed system allows for high performance and low-power ECG signal recording for the long-term and wearable applications.Keywords
This publication has 52 references indexed in Scilit:
- High density CMOS electrode array for high-throughput and automated cell countingSensors and Actuators B: Chemical, 2013
- Nanofiber Web Textile Dry Electrodes for Long-Term Biopotential RecordingIEEE Transactions on Biomedical Circuits and Systems, 2012
- Shear induced CNT/PDMS conducting thin film for electrode cardiogram (ECG) electrodeBioChip Journal, 2012
- Evaluation of crystalline perfection degree of multi‐walled carbon nanotubes: correlations between thermal kinetic analysis and micro‐Raman spectroscopyJournal of Raman Spectroscopy, 2010
- An ultra-high input impedance ECG amplifier for long-term monitoring of athletesMedical Devices: Evidence and Research, 2010
- A multichannel portable ECG system with capacitive sensorsPhysiological Measurement, 2008
- Flexible polymeric dry electrodes for the long-term monitoring of ECGSensors and Actuators A: Physical, 2008
- Supplemented standard 12-lead electrocardiogram for optimal diagnosis and reconstruction of significant body surface map patternsJournal of Electrocardiology, 2008
- Band-Tunable and Multiplexed Integrated Circuits for Simultaneous Recording and Stimulation With Microelectrode ArraysIEEE Transactions on Biomedical Engineering, 2005
- A low-power low-noise cmos for amplifier neural recording applicationsIEEE Journal of Solid-State Circuits, 2003