The Effect of Pressure and Temperature on Mid-Infrared Sensing of Dissolved Hydrocarbons in Water
- 29 November 2017
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (24) , 13391-13397
Abstract
Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy using a polymer coated internal reflection element/waveguide is an established sensor platform for the detection of a range of organic and hydrocarbon molecules dissolved in water. The polymer coating serves two purposes: to concentrate hydrocarbons from the aqueous phase and to exclude water along with other interfering molecules from the surface of the internal reflection element. Crucial to reliable quantification and analytical performance is the calibration of the ATR-FTIR sensor which is commonly performed in water under mild ambient conditions (i.e., 25 °C and 1 atm). However, there is a pressing need to monitor environmental and industrial processes/events that may occur at high pressures and temperatures where this calibration approach is unsuitable. Using a ruggedized optical fiber probe with a diamond-based ATR, we have conducted mid-infrared sensor experiments to understand the influence of high pressure (up to 207 bar) and temperature (up to 80 °C) on the detection of toluene and naphthalene dissolved in water. Using a poly(isobutylene) film, we have shown that the IR spectroscopic response is relatively unaffected by changes in pressure; however, a diminished response was observed with increasing temperature. We reveal that changes in the refractive index of the polymer film with temperature have only a minor effect on sensitivity. A more plausible explanation for the observed significant change in sensor response with temperature is that the partitioning process is exothermic and becomes less favorable with increasing temperature. This Article shows that the sensitivity is relatively invariant to pressure; however, the thermal variations are significant and need to be considered when quantifying the concentration of hydrocarbons in water.Keywords
Funding Information
- Commonwealth Scientific and Industrial Research Organisation
This publication has 49 references indexed in Scilit:
- Analysis of BTEX groundwater concentrations from surface spills associated with hydraulic fracturing operationsJournal of the Air & Waste Management Association, 2013
- Determination of volatile organic compounds in drinking and environmental watersTrAC Trends in Analytical Chemistry, 2012
- Feasibility of Monitoring Techniques for Substances Mobilised by CO2 Storage in Geological FormationsEnergy Procedia, 2012
- Composition and fate of gas and oil released to the water column during the Deepwater Horizon oil spillProceedings of the National Academy of Sciences, 2011
- Partitioning of semi-soluble organic compounds between the water phase and oil droplets in produced waterMarine Pollution Bulletin, 2004
- Progression of natural attenuation processes at a crude-oil spill siteJournal of Contaminant Hydrology, 2001
- Human toxicity potentials for life-cycle assessment and toxics release inventory risk screeningEnvironmental Toxicology and Chemistry, 2001
- The Transport and Fate of Ethanol and BTEX in Groundwater Contaminated by GasoholCritical Reviews in Environmental Science and Technology, 2001
- Identification of Polar, Ionic, and Highly Water Soluble Organic Pollutants in Untreated Industrial WastewatersEnvironmental Science & Technology, 1999
- Organic geochemistry applied to environmental assessments of Prince William Sound, Alaska, after the Exxon Valdez oil spill—a reviewOrganic Geochemistry, 1996