Cryogenic Test Facility CryoMaK
Authors:
- 21 November 2011
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 22 (3) , 9501204
Abstract
Within the growing field of cryogenic applications, there is an increasing demand on cryogenic material characterization. The Cryogenic Material Test Facility Karlsruhe CryoMaK is able to perform a variety of tests. The facility has a long standing tradition in cryogenic testing going back to 20 years in the Institute of Technical Physics at the Karlsruhe Institute of Technology (KIT). Mainly focused on mechanical testing also thermal conductivity and expansion measurements are performed. Additional test rigs are used to examine superconducting performance under applied tensile load in magnetic field.Keywords
This publication has 4 references indexed in Scilit:
- Electromechanical and Thermal Properties of Bi2223 TapesIEEE Transactions on Applied Superconductivity, 2007
- Transducers for Sub-Micron Displacement Measurements at Cryogenic TemperaturesAIP Conference Proceedings, 2006
- Strain sensing systems tailored for tensile measurement of fragile wiresSuperconductor Science and Technology, 2005
- The FBI Facility—A Test Rig for Critical Current Measurements on CICC as a Function of StrainIEEE Transactions on Applied Superconductivity, 2005