Open Access
Abstract
State-of-the-art radar systems for the contactless monitoring of vital signs and respiratory diseases are typically based on single-channel continuous wave (CW) technology. This technique allows precise measurements of respiration patterns, periods of movement, and heart rate. Major practical problems arise as CW systems suffer from signal cancellation due to destructive interference, limited overall functionality, and a possibility of low signal quality over longer periods. This work introduces a sophisticated multiple-input multiple-output (MIMO) solution that captures a radar image to estimate the sleep pose and position of a person (first step) and determine key vital parameters (second step). The first step is enabled by processing radar data with a forked convolutional neural network, which is trained with reference data captured by a time-of-flight depth camera. Key vital parameters that can be measured in the second step are respiration rate, asynchronous respiratory movement of chest and abdomen and limb movements. The developed algorithms were tested through experiments. The achieved mean absolute error (MAE) for the locations of the xiphoid and navel was less than 5 cm and the categorical accuracy of pose classification and limb movement detection was better than 90% and 98.6%, respectively. The MAE of the breathing rate was measured between 0.06 and 0.8 cycles per minute.Keywords
Funding Information
- Innosuisse - Schweizerische Agentur für Innovationsförderung (44973.1 IP-ENG)
This publication has 44 references indexed in Scilit:
- A dataset of clinically recorded radar vital signs with synchronised reference sensor signalsScientific Data, 2020
- Wearable radio-frequency sensing of respiratory rate, respiratory volume, and heart ratenpj Digital Medicine, 2020
- Contactless Respiration and Heartbeat Monitoring of Multiple People Using a 2-D Imaging Radar2019
- Devices for home detection of obstructive sleep apnea: A reviewSleep Medicine Reviews, 2018
- Through-Wall Human Pose Estimation Using Radio Signals2018
- Microwave Sleep Apnoea Monitoring2018
- Detection of respiratory paradoxical movement via Doppler radar measurements2014
- Obstructive Sleep Apnea as a Risk Factor for Stroke and DeathNew England Journal of Medicine, 2005
- Long-term cardiovascular outcomes in men with obstructive sleep apnoea-hypopnoea with or without treatment with continuous positive airway pressure: an observational studyThe Lancet, 2005
- Contactless respiration monitoring of infantsMedical & Biological Engineering & Computing, 1976