Uncertainties in planned dose due to the limited voxel size of the planning CT when treating lung tumors with proton therapy
Authors:
- 31 May 2011
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (13) , 3843-3856
Abstract
Dose calculation for lung tumors can be challenging due to the low density and the fine structure of the geometry. The latter is not fully considered in the CT image resolution used in treatment planning causing the prediction of a more homogeneous tissue distribution. In proton therapy, this could result in predicting an unrealistically sharp distal dose falloff, i.e. an underestimation of the distal dose falloff degradation. The goal of this work was the quantification of such effects. Two computational phantoms resembling a two-dimensional heterogeneous random lung geometry and a swine lung were considered applying a variety of voxel sizes for dose calculation. Monte Carlo simulations were used to compare the dose distributions predicted with the voxel size typically used for the treatment planning procedure with those expected to be delivered using the finest resolution. The results show, for example, distal falloff position differences of up to 4 mm between planned and expected dose at the 90% level for the heterogeneous random lung (assuming treatment plan on a 2 × 2 × 2.5 mm(3) grid). For the swine lung, differences of up to 38 mm were seen when airways are present in the beam path when the treatment plan was done on a 0.8 × 0.8 × 2.4 mm(3) grid. The two-dimensional heterogeneous random lung phantom apparently does not describe the impact of the geometry adequately because of the lack of heterogeneities in the axial direction. The differences observed in the swine lung between planned and expected dose are presumably due to the poor axial resolution of the CT images used in clinical routine. In conclusion, when assigning margins for treatment planning for lung cancer, proton range uncertainties due to the heterogeneous lung geometry and CT image resolution need to be considered.Keywords
This publication has 16 references indexed in Scilit:
- The effects of dose calculation resolution on dose accuracy for radiation therapy treatments of the lung. Part II. A comparison of dose distributions from an explicit lung model to dose distributions derived from a CT representationMedical Physics, 2010
- The effects of dose calculation resolution on dose accuracy for radiation therapy treatments of the lung. Part I. A Monte Carlo model of the lungMedical Physics, 2010
- A respiratory‐gated treatment system for proton therapyMedical Physics, 2007
- An anatomically realistic lung model for Monte Carlo‐based dose calculationsMedical Physics, 2007
- Target volume dose considerations in proton beam treatment planning for lung tumorsMedical Physics, 2005
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Effect of irradiated volume on lung damage in pigsRadiotherapy and Oncology, 1997
- The measurement of tissue heterodensity to guide charged particle radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1977
- Morphology of the bronchial tree in man.Journal of Applied Physiology, 1968
- A study of the subgross pulmonary anatomy in various mammalsJournal of Anatomy, 1961