Shake table tests on the out-of-plane response of unreinforced masonry wallsThis article is one of a selection of papers published in this Special Issue on Masonry.
Authors:
- 1 November 2007
- journal article
- Published by Canadian Science Publishing in Canadian Journal of Civil Engineering
- Vol. 34 (11) , 1381-1392
Abstract
Given sufficient anchorage to the diaphragms, out-of-plane walls in unreinforced masonry (URM) buildings have been shown to crack above midheight and then rock as two rigid bodies. This study investigates the sensitivity of the rocking response to the type of ground motion and the quality of the wall construction. Shake table tests were conducted on four full-scale multi-wythe walls, all with a height to thickness (h/t) ratio of 12 but of varying construction quality and subjected to three different ground motions. All walls experienced cracking at less than one half of the 2005 National Building Code of Canada (NBCC) level for Vancouver, but exhibited a stable rocking behaviour without collapse beyond a ground motion 1.5 times the 2005 NBCC level.Keywords
This publication has 4 references indexed in Scilit:
- Assessment of ASCE 41 Height‐to‐Thickness Ratio Limits for URM WallsEarthquake Spectra, 2007
- Experimental Investigation of Unreinforced Brick Masonry Walls in FlexureJournal of Structural Engineering, 2004
- Displacement‐based seismic analysis for out‐of‐plane bending of unreinforced masonry wallsEarthquake Engineering & Structural Dynamics, 2002
- Seismic Testing of Single‐Story Masonry Houses: Part 1Journal of Structural Engineering, 1990