Semi‐quantitative tracking of intra‐airway fluids by computed tomography
- 8 October 2009
- journal article
- research article
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 29 (6) , 406-413
Abstract
Airway secretions are a source of complications for patients with acute and chronic lung diseases, yet lack of techniques to quantitatively track secretions hampers research into clinical measures to reduce their pathologic consequences. In a preserved swine lung model, we tracked a contrasted mucus simulant (CMS) using sequential computed tomography (CT). Known drivers of secretion movement - gravity and ventilation - were tested. Ten millilitres of CMS were unilaterally introduced (1 ml min(-1)) into the airways of 12 lung sets. After instillation, six lung sets were maintained prone and six were rotated 180 degrees . Subsequently, all were mechanically ventilated for 10 min. CTs were obtained before infusion, after infusion and after ventilation +/- rotation. For CT analysis, the lungs were partitioned into eight sub-cuboids using anatomic landmarks. The volumes of two CT number ranges representing CMS and poor aeration/collapse were computed in every sub-cuboid for each CT acquisition. Volume differences between study time points were used to quantify changes. CMS and poor aeration/collapse volume change distributed gravitationally after infusion. After ventilation without rotation, the CMS and poor aeration/collapse volumes remained within the originally injected sub-cuboid, although the poor aeration/collapse volume expanded (27.3 +/- 6.1-->50.5 +/- 7.4 ml, P4.4 +/- 0.6 ml, P11.9 +/- 2.7 ml, P11.1 +/- 1.1 ml, P40.6 +/- 3.5 ml, P<0.05, respectively). Movement of fluids within the bronchial tree can be semi-quantitatively tracked with analysis of sequential CT acquisitions. In this isolated swine lung model, gravity had an important and brisk effect on movement of a viscous fluid, whereas ventilation tended to embed it peripherally.Keywords
This publication has 20 references indexed in Scilit:
- Propagation prevention: A complementary mechanism for “lung protective” ventilation in acute respiratory distress syndrome*Critical Care Medicine, 2008
- Alveolar edema dispersion and alveolar protein permeability during high volume ventilation: effect of positive end-expiratory pressureIntensive Care Medicine, 2007
- Virtual BronchoscopyProceedings of the American Thoracic Society, 2005
- Methodologic Aspects of Attenuation Distributions From Static and Dynamic Thoracic CT Techniques in Experimental Acute Lung InjuryChest, 2005
- Distribution dynamics of perfluorocarbon delivery to the lungs: an intact rabbit modelJournal of Applied Physiology, 2004
- Acute respiratory distress syndrome: Lessons from computed tomography of the whole lungCritical Care Medicine, 2003
- Bacterial colonization of the respiratory tract following tracheal intubation—Effect of gravity: An experimental study*Critical Care Medicine, 2003
- Prone position improves gas exchange – but how?Acta Anaesthesiologica Scandinavica, 2001
- Removal of Bronchial Secretions by Two-Phase Gas-Liquid TransportChest, 1989
- STUDIES ON THE PATHOGENESIS OF EXPERIMENTAL PNEUMOCOCCUS PNEUMONIA IN THE DOGJournal of Experimental Medicine, 1940