Representation of photon limited data in emission tomography using origin ensembles
Author:
- 27 May 2008
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (12) , 3201-3216
Abstract
Representation and reconstruction of data obtained by emission tomography scanners are challenging due to high noise levels in the data. Typically, images obtained using tomographic measurements are represented using grids. In this work, we define images as sets of origins of events detected during tomographic measurements; we call these origin ensembles (OEs). A state in the ensemble is characterized by a vector of 3N parameters Y, where the parameters are the coordinates of origins of detected events in a three-dimensional space and N is the number of detected events. The 3N-dimensional probability density function (PDF) for that ensemble is derived, and we present an algorithm for OE image estimation from tomographic measurements. A displayable image (e.g. grid based image) is derived from the OE formulation by calculating ensemble expectations based on the PDF using the Markov chain Monte Carlo method. The approach was applied to computer-simulated 3D list-mode positron emission tomography data. The reconstruction errors for a 10 000 000 event acquisition for simulated ranged from 0.1 to 34.8%, depending on object size and sampling density. The method was also applied to experimental data and the results of the OE method were consistent with those obtained by a standard maximum-likelihood approach. The method is a new approach to representation and reconstruction of data obtained by photon-limited emission tomography measurements.Keywords
This publication has 20 references indexed in Scilit:
- Image reconstructionPhysics in Medicine & Biology, 2006
- A Bayesian approach to characterizing uncertainty in inverse problems using coarse and fine-scale informationIEEE Transactions on Signal Processing, 2002
- Spatiotemporal reconstruction of list-mode PET dataIEEE Transactions on Medical Imaging, 2002
- Fully Bayesian estimation of Gibbs hyperparameters for emission computed tomography dataIEEE Transactions on Medical Imaging, 1997
- Evaluation of task-oriented performance of several fully 3D PET reconstruction algorithmsPhysics in Medicine & Biology, 1994
- SPECT reconstruction by simulated annealingPhysics in Medicine & Biology, 1989
- A Maximum Likelihood Method for Region-of-Interest Evaluation in Emission TomographyJournal of Computer Assisted Tomography, 1986
- An electronically collimated gamma camera for single photon emission computed tomography. Part II: Image reconstruction and preliminary experimental measurementsMedical Physics, 1983
- An electronically collimated gamma camera for single photon emission computed tomography. Part I: Theoretical considerations and design criteriaMedical Physics, 1983
- Monte Carlo sampling methods using Markov chains and their applicationsBiometrika, 1970