New Model for Estimating Glomerular Filtration Rate in Patients With Cancer
Authors:
- Tobias JanowitzTJTobias Janowitz
- Edward H. WilliamsEWEdward H. Williams
- Andrea MarshallAMAndrea Marshall
- Nicola AinsworthNANicola Ainsworth
- Peter B. ThomasPTPeter B. Thomas
- Stephen J. SammutSSStephen J. Sammut
- Scott ShepherdSSScott Shepherd
- Jeff WhiteJWJeff White
- Patrick B. MarkPMPatrick B. Mark
- Andy G. LynchALAndy G. Lynch
- Duncan I. JodrellDJDuncan I. Jodrell
- Simon TavaréSTSimon Tavaré
Open Access
- 20 August 2017
- journal article
- research article
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 35 (24) , 2798-2805
Abstract
Purpose: The glomerular filtration rate (GFR) is essential for carboplatin chemotherapy dosing; however, the best method to estimate GFR in patients with cancer is unknown. We identify the most accurate and least biased method.Methods: We obtained data on age, sex, height, weight, serum creatinine concentrations, and results for GFR from chromium-51 (51Cr) EDTA excretion measurements (51Cr-EDTA GFR) from white patients ≥ 18 years of age with histologically confirmed cancer diagnoses at the Cambridge University Hospital NHS Trust, United Kingdom. We developed a new multivariable linear model for GFR using statistical regression analysis.51Cr-EDTA GFR was compared with the estimated GFR (eGFR) from seven published models and our new model, using the statistics root-mean-squared-error (RMSE) and median residual and on an internal and external validation data set. We performed a comparison of carboplatin dosing accuracy on the basis of an absolute percentage error > 20%.Results: Between August 2006 and January 2013, data from 2,471 patients were obtained. The new model improved the eGFR accuracy (RMSE, 15.00 mL/min; 95% CI, 14.12 to 16.00 mL/min) compared with all published models. Body surface area (BSA)–adjusted chronic kidney disease epidemiology (CKD-EPI) was the most accurate published model for eGFR (RMSE, 16.30 mL/min; 95% CI, 15.34 to 17.38 mL/min) for the internal validation set. Importantly, the new model reduced the fraction of patients with a carboplatin dose absolute percentage error > 20% to 14.17% in contrast to 18.62% for the BSA-adjusted CKD-EPI and 25.51% for the Cockcroft-Gault formula. The results were externally validated.Conclusion: In a large data set from patients with cancer, BSA-adjusted CKD-EPI is the most accurate published model to predict GFR. The new model improves this estimation and may present a new standard of care.Keywords
This publication has 45 references indexed in Scilit:
- A comparison of measured and estimated glomerular filtration rate for carboplatin dose calculation in stage I testicular seminomaMedical Oncology, 2013
- Randomized Phase II/III Trial Assessing Gemcitabine/Carboplatin and Methotrexate/Carboplatin/Vinblastine in Patients With Advanced Urothelial Cancer Who Are Unfit for Cisplatin-Based Chemotherapy: EORTC Study 30986Journal of Clinical Oncology, 2012
- Drug dosing consideration in patients with acute and chronic kidney disease—a clinical update from Kidney Disease: Improving Global Outcomes (KDIGO)Kidney International, 2011
- Cross-validated stepwise regression for identification of novel non-nucleoside reverse transcriptase inhibitor resistance associated mutationsBMC Bioinformatics, 2011
- Mechanisms of Cisplatin NephrotoxicityToxins, 2010
- Phase II Evaluation of Paclitaxel and Carboplatin in the Treatment of Carcinosarcoma of the Uterus: A Gynecologic Oncology Group StudyJournal of Clinical Oncology, 2010
- Linear Model Selection by Cross-validationJournal of the American Statistical Association, 1993
- A comparative study of ordinary cross-validation, v-fold cross-validation and the repeated learning-testing methodsBiometrika, 1989
- Estimating the Dimension of a ModelThe Annals of Statistics, 1978
- Prediction of Creatinine Clearance from Serum CreatinineNephron, 1976