On-Line Measurement of Glucose in a Rotating Wall Perfused Vessel Bioreactor Using an Amperometric Glucose Sensor
Authors:
- 1 January 2002
- journal article
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 149 (4) , H103-H106
Abstract
A high performance, long-term, stable glucose sensor was developed and evaluated for continuous measurement of glucose for use in National Aeronautics and Space Administration space bioreactors while using a rotating wall perfused vessel system to support a baby hamster kidney (BHK-21) cell culture. The sensor employs a glucose oxidase multilayered membrane with a hydrogen peroxide electrode system. The output of the sensor was converted to glucose concentration utilizing the two-point calibration method. The sensor, tested over four 30 day bioreactor cell runs, showed a steady-state response time of less than 15 min. The sensor was able to measure glucose continuously and accurately for 16 days while using a single calibration and 30 days using two sets of calibrations, resulting in a standard error of prediction of ±0.5 mM±0.5 mM as against a benchtop Beckman glucose analyzer. Evaluation conditions like cell culture pH, incubator temperature conditions, and operational flow rate, were found to have a very little effect on the sensor performance. © 2002 The Electrochemical Society. All rights reserved.Keywords
This publication has 18 references indexed in Scilit:
- Electrochemical biosensors: recommended definitions and classificationBiosensors and Bioelectronics, 2001
- Miniaturized real-time monitoring system for l-lactate and glucose using microfabricated multi-enzyme sensorsBiosensors and Bioelectronics, 2000
- Fiber-Optic Chemical Sensors and BiosensorsAnalytical Chemistry, 2000
- Optical glucose sensing in biological fluids: an overviewJournal of Biomedical Optics, 2000
- A new glucose sensor based on encapsulated glucose oxidase within organically modified sol–gel glassSensors and Actuators B: Chemical, 1999
- Assessment of Chronically Implanted Subcutaneous Glucose Sensors in DogsASAIO Journal, 1999
- SPR immunosensor integrated two miniature enzyme sensorsSensors and Actuators B: Chemical, 1999
- Simultaneous monitoring of glucose and l-lactic acid during a fermentation process in an aqueous two-phase system by on-line FIA with microdialysis sampling and dual biosensor detectionAnalytica Chimica Acta, 1998
- Application of enzyme-field effect transistor sensor arrays as detectors in a flow-injection analysis system for simultaneous monitoring of medium components. Part II. Monitoring of cultivation processesAnalytica Chimica Acta, 1995
- Sequential injection: a new concept for chemical sensors, process analysis and laboratory assaysAnalytica Chimica Acta, 1990