Transformer Resonance: Reasons, Modeling Approaches, Solutions
Open Access
- 9 June 2023
- journal article
- review article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 58692-58704
Abstract
Due to the extension of the power grid with many complex and compact pieces of power equipment, transformers will be more exposed to fast transient, resulting from various resonance conditions. Transformer resonance can result in severe overvoltage on internal parts of the winding, leading to insulation failure and, consequently, transformer outage. The main reasons for resonance occurrence, the practical method to measure the resonance of transformers, and the solution for preventing transformer resonances have been discussed in the scientific reports over the past few decades; however, a comprehensive review of these studies is not present in the literature. Hence this paper aims to provide a comprehensive review to categorize the main reasons for transformer resonance, modeling methods, and appropriate solutions to suppress this phenomenon and suggest some prospective protection for future works.Keywords
Funding Information
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (18.699)
This publication has 84 references indexed in Scilit:
- Internal Winding Failure Due to Resonance Overvoltage in Distribution Transformer Caused by Winter LightningIEEE Transactions on Power Delivery, 2006
- Experimental Studies on the Use of MOV in Transformer Windings Inner ProtectionIEEE Transactions on Power Delivery, 2005
- Damping of Resonances at Energization of Transformers Serving Large Pulse-Type LoadsIEEE Transactions on Industry Applications, 2004
- Computation of very fast transient overvoltages in transformer windingsIEEE Transactions on Power Delivery, 2003
- A systematical method for suppressing ferroresonance at neutral-grounded substationsIEEE Transactions on Power Delivery, 2003
- Investigation of the circuit breaker reignition overvoltages caused by no‐load transformer switching surgesEuropean Transactions on Electrical Power, 2001
- Overvoltages due to switching off an unloaded transformer with a vacuum circuit breakerIEEE Transactions on Power Delivery, 1999
- Overvoltages in power transformers caused by no-load switchingIEEE Transactions on Power Delivery, 1995
- Power transformer resonance-measurements and predictionIEEE Transactions on Power Delivery, 1992
- Transformer model for high frequenciesIEEE Transactions on Power Delivery, 1988