Three‐dimensional late gadolinium‐enhanced mr imaging of the left atrium: A comparison of spiral versus Cartesian k‐space trajectories
- 4 September 2013
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 39 (1) , 211-216
Abstract
Purpose: To investigate the feasibility of high‐resolution late gadolinium enhancement (LGE) imaging using a three‐dimensional (3D) stack of spirals k‐space trajectory for the detection of left atrial (LA) ablation lesions. LGE imaging inherently suffers from low SNR, so that improvements in spatial resolution and imaging time are challenging. The spiral trajectory offers greater acquisition efficiency, and this is used for increased spatial resolution.Materials and Methods: Nine healthy subjects and 10 pre/post pulmonary vein isolation patients underwent an MRI examination. A Cartesian 3D inversion‐recovery gradient‐echo sequence was performed followed by a 3D inversion‐recovery gradient‐echo with a spiral trajectory. Image quality, fat suppression and sharpness were graded by expert cardiologists.Results: No statistical significance was determined for SNR or image quality between the Cartesian and spiral images; however, fat suppression was significantly improved with the spiral approach (P = 0.002). The enhancement in the Cartesian scan was found to have significantly higher CNR (P = 0.02).Conclusion: The feasibility of spiral LGE in the left atrium has been demonstrated. Similar image quality and sharpness were observed with both acquisitions. This spiral sequence has sub‐millimeter spatial resolution improved fat suppression and maintains a comparable level of SNR compared with the Cartesian scan. J. Magn. Reson. Imaging 2014;39:211–216.Keywords
This publication has 21 references indexed in Scilit:
- Noncontrast SSFP pulmonary vein magnetic resonance angiography: Impact of off‐resonance and flowJournal of Magnetic Resonance Imaging, 2010
- Detection and Quantification of Left Atrial Structural Remodeling With Delayed-Enhancement Magnetic Resonance Imaging in Patients With Atrial FibrillationCirculation, 2009
- Fast conjugate phase image reconstruction based on a Chebyshev approximation to correct for B0 field inhomogeneity and concomitant gradientsMagnetic Resonance in Medicine, 2008
- New Magnetic Resonance Imaging-Based Method for Defining the Extent of Left Atrial Wall Injury After the Ablation of Atrial FibrillationJACC, 2008
- Arrhythmia Recurrence After Atrial Fibrillation Ablation: Can Magnetic Resonance Imaging Identify Gaps in Atrial Ablation Lines?Journal of Cardiovascular Electrophysiology, 2007
- Anatomy of the Left Atrium:Journal of Cardiovascular Electrophysiology, 1999
- Fast Three Dimensional Magnetic Resonance ImagingMagnetic Resonance in Medicine, 1995
- Selection of a convolution function for Fourier inversion using gridding (computerised tomography application)IEEE Transactions on Medical Imaging, 1991
- Fast gradient‐echo chemical‐shift imagingMagnetic Resonance in Medicine, 1988
- A new method for water suppression in the proton NMR spectra of aqueous solutionsJournal of Magnetic Resonance (1969), 1983