Effect of Pupil Size on Optical Quality Parameters in Astigmatic Eyes Using a Double-Pass Instrument
Open Access
- 23 June 2013
- journal article
- research article
- Published by Wiley in BioMed Research International
- Vol. 2013, 1-6
Abstract
Purpose. To objectively determine the effects of pupil size on optical quality parameters in astigmatic eyes using a double-pass instrument. Methods. We examined twenty-two eyes of 22 healthy volunteers (mean age±standard deviation, years) who had no ophthalmic diseases other than refractive errors (manifest cylinder 0.25 diopters (D)). After we fully corrected cycloplegic refraction, we created with-the-rule astigma tism of 1, 2, and 3 diopters in these eyes and then quantitatively assessed the modulation transfer function (MTF) cutoff frequency and the Strehl2D ratio with 2-, 4-, and 6-mm pupil sizes using the Optical Quality Analysis System. Results. The MTF cutoff frequency and the Strehl2D ratio decreased significantly as the amount of astigmatism increased at each pupil size ( for 2, 4, and 6mm, analysis of variance). They also decreased significantly with an increase in pupil size at each diopter of astigmatism ( for 0, 1, 2, and 3 D). Multiple comparisons demonstrated a significant difference between measurements made for a 2-mm pupil and for a 6-mm pupil at each diopter of astigmatism ( for 0, 1, 2, and 3 D, Dunnett test) and those made for a 4-mm pupil and for a 6-mm pupil at each diopter of astigmatism ( for 0 D, 1, 2, and 3 D). Conclusions. Eyes with larger pupils had lower optical quality even when they were astigmatic. It may be necessary to correct the preexisting astigmatism to acquire excellent visual performance, especially in astigmatic eyes with larger pupils.Keywords
This publication has 16 references indexed in Scilit:
- Effect of pupil size on uncorrected visual acuity in astigmatic eyesBritish Journal of Ophthalmology, 2011
- Intra‐ and Intersession Repeatability of a Double‐Pass InstrumentOptometry and Vision Science, 2010
- Analysis of biometry and prevalence data for corneal astigmatism in 23 239 eyesJournal of Cataract & Refractive Surgery, 2010
- Repeatability of measurements with a double-pass systemJournal of Cataract & Refractive Surgery, 2010
- Prevalence of corneal astigmatism before cataract surgeryJournal of Cataract & Refractive Surgery, 2009
- Image quality with multifocal intraocular lenses and the effect of pupil sizeJournal of Cataract & Refractive Surgery, 2007
- Optical Quality Analysis SystemJournal of Cataract & Refractive Surgery, 2004
- Monochromatic modulation transfer function of the human eye for different pupil diameters: an analytical expressionJournal of the Optical Society of America A, 1994
- Modulation transfer of the human eye as a function of retinal eccentricityJournal of the Optical Society of America A, 1993
- The Effect of Pupil Size on Visual Acuity in Uncorrected and Corrected MyopiaOptometry and Vision Science, 1979