Novel spatiotemporal processing tools for body-surface potential map signals for the prediction of catheter ablation outcome in persistent atrial fibrillation
Open Access
- 29 September 2022
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 13, 1001060
Abstract
Background: Signal processing tools are required to efficiently analyze data collected in body-surface-potential map (BSPM) recordings. A limited number of such tools exist for studying persistent atrial fibrillation (persAF). We propose two novel, spatiotemporal indices for processing BSPM data and test their clinical applicability through a comparison with the recently proposed non-dipolar component index (NDI) for prediction of single-procedure catheter ablation (CA) success rate in persAF patients.Methods: BSPM recordings were obtained with a 252-lead vest in 13 persAF patients (8 men, 63 ± 8 years, 11 ± 13 months sustained AF duration) before undergoing CA. Each recording was divided into seven 1-min segments of high signal quality. Spatiotemporal ventricular activity (VA) cancellation was applied to each segment to isolate atrial activity (AA). The two novel indices, called error-ratio, normalized root-mean-square error (ERNRMSE) and error-ratio, mean-absolute error (ERABSE), were calculated. These indices quantify the capacity of a subset of BSPM vest electrodes to accurately represent the AA, and AA dominant frequency (DF), respectively, on all BSPM electrodes over time, compared to the optimal principal component analysis (PCA) representation. The NDI, quantifying the fraction of energy retained after removal of the three largest PCs, was also calculated. The two novel indices and the NDI were statistically compared between patient groups based on single-procedure clinical CA outcome. Finally, their predictive power for univariate CA outcome classification was assessed using receiver operating characteristic (ROC) analysis with cross-validation for a logistic regression classifier.Results: Patient clinical outcomes were recorded 6 months following procedures, and those who had an arrhythmia recurrence at least 2 months post-CA were defined as having a negative outcome. Clinical outcome information was available for 11 patients, 6 with arrhythmia recurrence. Therefore, a total of 77 1-min AA-BSPM segments were available for analysis. Significant differences were found in the values of the novel indices and NDI between patients with arrhythmia recurrence post-ablation and those without. ROC analysis showed the best CA outcome predictive performance for ERNRMSE (AUC = 0.77 ± 0.08, sensitivity = 76.2%, specificity = 84.8%).Conclusion: Significant association was found between the novel indices and CA success or failure. The novel index ERNRMSE additionally shows good predictive power for single-procedure CA outcome.Keywords
This publication has 22 references indexed in Scilit:
- Adaptive frequency tracking of the baseline ECG identifies the site of atrial fibrillation termination by catheter ablationBiomedical Signal Processing and Control, 2013
- Catheter ablation outcome prediction in persistent atrial fibrillation using weighted principal component analysisBiomedical Signal Processing and Control, 2013
- Noninvasive Localization of Maximal Frequency Sites of Atrial Fibrillation by Body Surface Potential MappingCirculation: Arrhythmia and Electrophysiology, 2013
- Spatial complexity and spectral distribution variability of atrial activity in surface ECG recordings of atrial fibrillationMedical & Biological Engineering & Computing, 2012
- Manifestation of Left Atrial Events and Interatrial Frequency Gradients in the Surface Electrocardiogram During Atrial Fibrillation: Contributions from Posterior LeadsJournal of Cardiovascular Electrophysiology, 2009
- Evaluation of lead selection methods for optimal reconstruction of body surface potentialsJournal of Electrocardiology, 2008
- Principal Component Analysis in ECG Signal ProcessingEURASIP Journal on Advances in Signal Processing, 2007
- Adaptation of the standard 12-lead electrocardiogram system dedicated to the analysis of atrial fibrillationJournal of Electrocardiology, 2007
- Comparison of Atrial Signal Extraction Algorithms in 12-Lead ECGs With Atrial FibrillationIEEE Transactions on Biomedical Engineering, 2006
- Spatiotemporal QRST cancellation techniques for analysis of atrial fibrillationIEEE Transactions on Biomedical Engineering, 2001