Computer-aided parachute guiding system for closed reduction of diaphyseal fractures
- 13 September 2013
- journal article
- research article
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 10 (3) , 325-331
Abstract
Background Closed reduction is of great benefit for fracture healing. However, achieving this without sacrificing the reduction accuracy and exposing the surgeon and patient to excessive radiation is difficult. Methods A novel parachute guiding system (ParaEx System) was developed for closed reduction of fractures based on computed tomography data. The system included two counter guides with stainless tubular markers that could be attached to the unilateral external fixator. Comminuted tibial diaphyseal fracture models were used to validate the ParaEx System. Results The mean errors (and standard deviations) of residual rotational and translational deformity were 0.67° ± 0.45°, 0.92° ± 1.00°, and 0.64° ± 0.50° in rotation and 1.30 ± 1.10 mm, 1.13 ± 0.70 mm, and 0.94 ± 0.92 mm in translation about the X, Y, and Z axes of the local coordinate axes, respectively. Conclusions The ParaEx System was useful for accurate closed reduction of fractures at low cost. Copyright © 2013 John Wiley & Sons, Ltd.Keywords
This publication has 23 references indexed in Scilit:
- Comparison of three dimensional and radiographic measurements in the analysis of distal radius malunionJournal of Hand Surgery (European Volume), 2012
- Novel 3D hexapod computer‐assisted orthopaedic surgery system for closed diaphyseal fracture reductionThe International Journal of Medical Robotics and Computer Assisted Surgery, 2011
- Three-dimensional analysis of cubitus varus deformity after supracondylar fractures of the humerusJournal of Shoulder and Elbow Surgery, 2011
- Navigation Reduces the Learning Curve in Resurfacing Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2007
- Development and validation of a new approach for computer-aided long bone fracture reduction using unilateral external fixatorJournal of Biomechanics, 2006
- Three-dimensional load measurements in an external fixatorJournal of Biomechanics, 2004
- A hexapod robot external fixator for computer assisted fracture reduction and deformity correctionThe International Journal of Medical Robotics and Computer Assisted Surgery, 2004
- Nonunions of the HumerusClinical Orthopaedics and Related Research, 2004
- Twins and twinning, dentists and dentistryAustralian Dental Journal, 1990
- Marching cubes: A high resolution 3D surface construction algorithmACM SIGGRAPH Computer Graphics, 1987