Research on Bowden Cable–Fabric Force Transfer System Based on Force/Displacement Compensation and Impedance Control
Open Access
- 27 October 2023
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 13 (21) , 11766
Abstract
Bowden cable–fabric is a key force transfer device for flexible exoskeletons, and its precise control of force/displacement is a significant factor in the human–machine interaction of flexible exoskeletons. In this paper, a force/displacement control method based on friction compensation and impedance control was proposed based on a flexible Bowden cable–fabric force transfer testbed system. First, a set of in vitro experimental platforms simulating Bowden cable–fabric force transfer was built according to a typical flexible exoskeleton force transfer system, and following the walking gait of lower limbs, the expected force and knee joint motion were set. Secondly, the Bowden cable–fabric force transfer friction model was constructed as the basis of the system’s force transfer compensation. In addition, the stiffness model of Bowden cable–fabric and the lower leg movement model were established and combined with impedance control to realize the precise control of system displacement. Finally, the damping and stiffness parameters suitable for the system were obtained through the impedance control simulation. In terms of the experiment, an in vitro Bowden cable–fabric force transfer experimental platform was built, and the expected force with the input peak value of 40 N, 50 N, and 60 N was set. Through the friction and position compensation model of Bowden cable–fabric force transfer and impedance control, the relative root-mean-square errors of the output force and expected force were obtained as 2.53%, 2.16%, and 2.07%, respectively. Therefore, the effectiveness of the proposed method is verified, which provides a foundation for the engineering application of flexible exoskeletons.Keywords
Funding Information
- National Natural Science Foundation of China (62103007, L202020, 110051360023XN224-32)
- Natural Science Foundation of Beijing Municipality (62103007, L202020, 110051360023XN224-32)
- Launching Scientific Research Funds of North China University of Technology (62103007, L202020, 110051360023XN224-32)
This publication has 19 references indexed in Scilit:
- Cross-wire assist suit concept, for mobile and lightweight multiple degree of freedom hip assistance2017
- Modeling and motion compensation of a bidirectional tendon-sheath actuated system for robotic endoscopic surgeryComputer Methods and Programs in Biomedicine, 2015
- Autonomous exoskeleton reduces metabolic cost of human walking during load carriageJournal of NeuroEngineering and Rehabilitation, 2014
- Haptic feedback and control of a flexible surgical endoscopic robotComputer Methods and Programs in Biomedicine, 2013
- Inverse Transmission Model and Compensation Control of a Single-Tendon–Sheath ActuatorIEEE Transactions on Industrial Electronics, 2013
- Tendon sheath analysis for estimation of distal end force and elongation for sensorless distal endRobotica, 2010
- Development of single leg version of HAL for hemiplegia2009
- Verification of Flexible Actuator From Position and Force Transfer Characteristic and Its Application to Bilateral Teleoperation SystemIEEE Transactions on Industrial Electronics, 2008
- Capstan equation including bending rigidity and non-linear frictional behaviorMechanism and Machine Theory, 2008
- An Improved Capstan Equation for Nonflexible Fibers and YarnsTextile Research Journal, 1998