A Contribution to the Investigation of Leader Tortuosity in Positive Long Rod-Plane Air Discharge
Authors:
Open Access
- 20 November 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 170442-170447
Abstract
In recent years, the investigation of leader tortuosity in long air discharge is brought into focus, for it is the main factor that influents the 50% breakdown voltage and can be used to validate and test the discharge modes in the design of long air gap dimension. In order to find out whether the test data of the whole leader channels are accuracy to represent the leader propagation paths, a discharge test of a 4 m rod-plane air gap subjected to switching impulse voltage is carried out. And an observation platform is set up to synchronously record the voltage waveforms, the discharge currents, the leader propagation processes and the whole leader channels. A new method is proposed to subtract the final-jump part from the whole leader channel by identifying the leader tip height at the initiation of the final jump (LTH for short) from the CCD image. Then the test data of LTH and the leader propagation path are statistically obtained. And probability density functions (PDFs for short) of three different angles between consecutive segments of the leader propagation path are used to quantitatively describe the leader tortuosity. According to the analysis of the results, the mean value of LTH is nearly half the gap length in the gap axial direction. And an obvious difference can be discovered when comparing PDFs of the leader propagation paths with those of the whole leader channels. A conclusion to account for the difference is deduced that the leader paths during the final jump are much straighter than those during leader propagation. In the end, the present work recommends that the final-jump part should be subtracted from the whole leader channel when the test data of leader tortuosity are used in the numerical model for positive long air discharge.Keywords
This publication has 26 references indexed in Scilit:
- A consistent approach to estimate the breakdown voltage of high voltage electrodes under positive switching impulsesJournal of Applied Physics, 2013
- Digital time-resolved optical measurement of discharge currents in long air gapsReview of Scientific Instruments, 2013
- Numerical simulation of long laboratory sparks generated by positive switching impulsesJournal of Electrostatics, 2009
- A self-consistent upward leader propagation modelJournal of Physics D: Applied Physics, 2006
- A Simplified Physical Model to Determine the Lightning Upward Connecting Leader InceptionIEEE Transactions on Power Delivery, 2006
- A simplified model for the simulation of positive-spark development in long air gapsJournal of Physics D: Applied Physics, 1997
- Theoretical modelling of the development of the positive spark in long gapsJournal of Physics D: Applied Physics, 1994
- A model for switching impulse leader inception and breakdown of long air-gapsIEEE Transactions on Power Delivery, 1989
- Switching impulse strength of air insulation: leader inception criterionIEEE Transactions on Power Delivery, 1989
- The mechanism of the long spark formationLe Journal de Physique Colloques, 1979