Uterine fibroids: correlations between MRI appearance and stiffness via magnetic resonance elastography
Authors:
- Danielle E. JondalDJDanielle E. Jondal
- Jin WangJWJin Wang
- Jun ChenJCJun Chen
- Krzysztof R. GornyKGKrzysztof R. Gorny
- Joel FelmleeJFJoel Felmlee
- Gina HeslyGHGina Hesly
- Shannon Laughlin-TommasoSLShannon Laughlin-Tommaso
- Elizabeth A. StewartESElizabeth A. Stewart
- Richard EhmanRERichard Ehman
- David A. WoodrumDWDavid A. Woodrum
- 26 September 2017
- journal article
- research article
- Published by Springer Nature in Abdominal Radiology
- Vol. 43 (6) , 1456-1463
Abstract
Rationale and objectives Magnetic resonance elastography has proven to be a valuable tool in the diagnosis of liver fibrosis, breast and cervical cancer, but its application in uterine fibroids requires further characterization. The aim of the present study was to examine the relationship between uterine fibroid stiffness by MRE and MR imaging characteristics. Materials and methods An IRB-approved, HIPAA compliant review was performed of prospectively collected pelvic MRI and 2D-MRE data in patients with symptomatic uterine fibroids (N = 102). T1 and T2 weighted pelvic MRI with gadolinium enhancement were performed. In a small patient subset, fibroid stiffness was assessed by both 2D and 3D MRE. Fibroid stiffness by modality or imaging characteristics was analyzed using one-way analysis of variance followed by Student t test. Results Four fibroid groups were identified based on T2 appearance: Isointense (N = 7), bright (N = 6), dark with minimal heterogeneity (N = 69), and dark with substantial heterogeneity (N = 20). Mean fibroid stiffness was 4.81 ± 2.12 kPa. Comparison of fibroid stiffness by T2 signal intensity showed that T2 bright fibroids were significantly less stiff than fibroids appearing T2 dark with minimal heterogeneity (mean stiffness difference = 2.38 kPa; p < 0.05) and T2 dark fibroids with substantial heterogeneity were significantly less stiff than T2 dark fibroids with minimal heterogeneity (mean difference = 1.25 kPa; p < 0.05). There was no significant association between fibroid stiffness and T1 signal characteristics or gadolinium enhancement. There was no significant difference in stiffness values obtained by either 2D vs. 3D MRE. Conclusions These data suggest differences in fibroid stiffness are associated with different T2 imaging characteristics with less stiff fibroids being T2 bright and more stiff fibroids being T2 dark. Further studies are needed to determine if fibroid stiffness by MRE may serve as an imaging biomarker to help predict MR-guided treatment response.Keywords
This publication has 30 references indexed in Scilit:
- Magnetic Resonance Elastography in the Diagnosis of Hepatic FibrosisSeminars in Ultrasound, CT and MRI, 2013
- Characterization of tissue biomechanics and mechanical signaling in uterine leiomyomaMatrix Biology, 2012
- Magnetic resonance elastography of uterine leiomyomas: a feasibility studyFertility and Sterility, 2011
- Magnetic resonance elastography: A reviewClinical Anatomy, 2010
- Incidence, aetiology and epidemiology of uterine fibroidsBest Practice & Research Clinical Obstetrics & Gynaecology, 2008
- Magnetic Resonance Elastography for the Noninvasive Staging of Liver FibrosisGastroenterology, 2008
- Mechanical homeostasis is altered in uterine leiomyomaAmerican Journal of Obstetrics and Gynecology, 2008
- The second National Institutes of Health International Congress on advances in uterine leiomyoma research: conference summary and future recommendationsFertility and Sterility, 2006
- Noninvasive assessment of liver fibrosis by measurement of stiffness in patients with chronic hepatitis CHepatology, 2004
- Magnetic Resonance Elastography by Direct Visualization of Propagating Acoustic Strain WavesScience, 1995