Diffusion tensor magnetic resonance imaging of the normal breast: reproducibility of DTI-derived fractional anisotropy and apparent diffusion coefficient at 3.0 T
Authors:
- 14 May 2012
- journal article
- research article
- Published by Springer Nature in La radiologia medica
- Vol. 117 (6) , 992-1003
Abstract
Purpose Diffusion-weighted imaging (DWI) may improve the diagnostic performance of conventional breast magnetic resonance imaging (MRI). Diffusion tensor imaging (DTI) is an extension of DWI. If DTI-derived measurements are to be clinically useful, particularly for predicting and/or monitoring therapeutic effects, they must be robust and reliable. The purpose of this study was to assess intra- and interobserver reproducibility of DTIderived fractional anisotropy (FA) and apparent diffusion coefficient (ADC) at 3.0 T. Materials and methods This prospective study was approved by the Institutional Review Board, and participants provided written informed consent. Sixty normal contralateral breasts of 60 patients (28–85 years, median 57) were analysed with a DWI sequence following a standard MRI protocol. Four authors performed all postprocessing and analyses independently and in different sessions. The same authors, blinded to the initial results, repeated the image postprocessing and analysis 4 weeks after the initial session. Results Mean ADC and FA for DTI sequences were, respectively, 1.92±0.30 and 0.32±0.09. Intra- and seinterobserver agreement of the four radiologists for ADC and FA were good (acceptable). Kappa values for ADC were intra-R1=0.82; intra-R2=0.84; intra-R3=0.89; intra-R4=0.88; inter-R1-R2=0.73; inter-R1-R3=0.74; inter-R1-R4=0.81; inter-R2-R3=0.76; inter-R2-R4=0.77; inter-R3-R4=0.83. Kappa values for FA were intra-R1=0.60; intra-R2=0.72; intra-R3=0.84; intra-R4 = 0.66; inter-R1-R2=0.64; inter-R1-R3=0.69; inter-R1-R4=0.72; inter-R2-R3=0.80; inter-R2-R4=0.71; inter-R3-R4=0.73. Within-subject coefficient of variation was 15% for ADC and 30% for FA. Repeatability with α=0.05 was 0.37×10−3 mm2/s for ADC and 0.112 for FA. Conclusions ADC and FA measurements obtained with DTI are reproducible and may be valid, reliable and sensitive to change. ADC values obtained with DTI are more reproducible than FA.Keywords
This publication has 38 references indexed in Scilit:
- Tumour ADC measurements in rectal cancer: effect of ROI methods on ADC values and interobserver variabilityEuropean Radiology, 2011
- Diffusion-weighted MR Imaging: Pretreatment Prediction of Response to Neoadjuvant Chemotherapy in Patients with Breast CancerRadiology, 2010
- Diffusion-weighted Imaging Improves the Diagnostic Accuracy of Conventional 3.0-T Breast MR ImagingRadiology, 2010
- Magnetic resonance imaging of the breast: Recommendations from the EUSOMA working groupEuropean Journal of Cancer, 2010
- Diffusion Tensor Imaging of the Kidney With Parallel Imaging: Initial Clinical ExperienceInvestigative Radiology, 2008
- ADC value and diffusion tensor imaging of prostate cancer: Changes in carbon‐ion radiotherapyJournal of Magnetic Resonance Imaging, 2008
- Diffusion Tensor Magnetic Resonance Imaging of Prostate CancerInvestigative Radiology, 2007
- Quantitative diffusion imaging in breast cancer: A clinical prospective studyJournal of Magnetic Resonance Imaging, 2006
- Water diffusion in the different microenvironments of breast cancerNMR in Biomedicine, 2004
- Differentiation of clinically benign and malignant breast lesions using diffusion‐weighted imagingJournal of Magnetic Resonance Imaging, 2002