A Detailed Model of Electroenzymatic Glutamate Biosensors To Aid in Sensor Optimization and in Applications in Vivo
- 10 November 2017
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Chemical Neuroscience
- Vol. 9 (2) , 241-251
Abstract
Simulations conducted with a detailed model of glutamate biosensor performance describe the observed sensor performance well, illustrate the limits of sensor performance, and suggest a path toward sensor optimization. Glutamate is the most important excitatory neurotransmitter in the brain, and electroenzymatic sensors have emerged as a useful tool for the monitoring of glutamate signaling in vivo. However, the utility of these sensors currently is limited by their sensitivity and response time. A mathematical model of a typical glutamate biosensor consisting of a Pt electrode coated with a permselective polymer film and a top layer of cross-linked glutamate oxidase has been constructed in terms of differential material balances on glutamate, H2O2, and O2 in one spatial dimension. Simulations suggest that reducing thicknesses of the permselective polymer and enzyme layers can increase sensitivity ∼6-fold and reduce response time ∼7-fold, and thereby improve resolution of transient glutamate signals. At currently employed enzyme layer thicknesses, both intrinsic enzyme kinetics and enzyme deactivation likely are masked by mass transfer. However, O2-dependence studies show essentially no reduction in signal at the lowest anticipated O2 concentrations for expected glutamate concentrations in the brain and that O2 transport limitations in vitro are anticipated only at glutamate concentrations in the mM range. Finally, the limitations of current biosensors in monitoring glutamate transients is simulated and used to illustrate the need for optimized biosensors to report glutamate signaling accurately on a subsecond time scale. This work demonstrates how a detailed model can be used to guide optimization of electroenzymatic sensors similar to that for glutamate and to ensure appropriate interpretation of data gathered using such biosensors.Keywords
Funding Information
- National Institute of Neurological Disorders and Stroke (R01NS087494)
This publication has 68 references indexed in Scilit:
- Highly selective and stable microdisc biosensors for l-glutamate monitoringSensors and Actuators B: Chemical, 2013
- Transient Extracellular Glutamate Events in the Basolateral Amygdala Track Reward-Seeking ActionsJournal of Neuroscience, 2012
- Optimizing the Temporal Resolution of Fast-Scan Cyclic VoltammetryACS Chemical Neuroscience, 2012
- Diffuse Brain Injury Elevates Tonic Glutamate Levels and Potassium-Evoked Glutamate Release in Discrete Brain Regions at Two Days Post-Injury: An Enzyme-Based Microelectrode Array StudyJournal of Neurotrauma, 2010
- Chronic microsensors for longitudinal, subsecond dopamine detection in behaving animalsNature Methods, 2009
- Measuring oxygen, carbon monoxide and hydrogen sulfide diffusion coefficient and solubility in Nafion membranesElectrochimica Acta, 2009
- Silicon Wafer-Based Platinum Microelectrode Array Biosensor for Near Real-Time Measurement of Glutamate in VivoSensors, 2008
- On the porosity of polypyrrole filmsSynthetic Metals, 2007
- Electrochemical oxidation of hydrogen peroxide at platinum electrodes. Part V: inhibition by chlorideElectrochimica Acta, 2000
- Electrochemical oxidation of hydrogen peroxide at platinum electrodes. Part IV: phosphate buffer dependenceElectrochimica Acta, 1999