A new EPI‐based dynamic field mapping method: Application to retrospective geometrical distortion corrections
Open Access
- 29 August 2007
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 26 (3) , 747-755
Abstract
Purpose To retrospectively correct for geometrical distortions, a new dynamic field mapping method suitable for dynamic single-shot gradient-echo type echo-planar imaging (GRE-EPI) is proposed. Materials and Methods The method requires a single volume additional acquisition and allows the extraction of a field map from each phase volume, assuming invariance across time of the echo time-independent phase component. Performances of the method are assessed using three sets of experiments: the first tests the prerequisite and the modeling; the second tests the method with time-dependent geometrical distortions; and the third presents a comparison with two other methods. Results Our results legitimize the modeling procedure and demonstrate that the dynamic method is less sensitive to noise than the other methods. A theoretical explanation for this is proposed in the discussion section. Conclusion Given the minor increase in the acquisition time, this method is well suited for functional magnetic resonance imaging; prospective direction. J. Magn. Reson. Imaging 2007;26:747–755.Keywords
This publication has 36 references indexed in Scilit:
- New approach for correcting distortions in echo planar imagingMagnetic Resonance in Medicine, 2004
- Point spread function mapping with parallel imaging techniques and high acceleration factors: Fast, robust, and flexible method for echo‐planar imaging distortion correctionMagnetic Resonance in Medicine, 2004
- Real‐time autoshimming for echo planar timecourse imagingMagnetic Resonance in Medicine, 2002
- Image distortion correction in EPI: Comparison of field mapping with point spread function mappingMagnetic Resonance in Medicine, 2002
- Image Distortion Correction in fMRI: A Quantitative EvaluationNeuroImage, 2002
- Artifact due to B0 fluctuations in fMRI: Correction using the k‐space central lineMagnetic Resonance in Medicine, 2001
- Inadequacy of motion correction algorithms in functional MRI: Role of susceptibility‐induced artifactsJournal of Magnetic Resonance Imaging, 1997
- Fast interleaved echo‐planar imaging with navigator: High resolution anatomic and functional images at 4 teslaMagnetic Resonance in Medicine, 1996
- Diffusion‐weighted interleaved echo‐planar imaging with a pair of orthogonal navigator echoesMagnetic Resonance in Medicine, 1996
- Analysis of T2 limitations and off‐resonance effects on spatial resolution and artifacts in echo‐planar imagingMagnetic Resonance in Medicine, 1990