Establishing local diagnostic reference levels for common orthopaedic procedures using the mini C-arm fluoroscope
- 22 October 2020
- journal article
- research article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 94 (1117) , 20190878
Abstract
Objective: Mini C-arm fluoroscopes are widely used by orthopaedic surgeons for intraoperative image guidance without the need for radiographers. This puts the responsibility for radiation exposure firmly with the operating surgeon. In order to maintain safe and best practice under U.K. Ionising Radiation (Medical Exposure) Regulations, one must limit radiation exposure and audit performance using national diagnostic reference levels (DRLs). In the case of the mini C-arm, there are no national DRLs. IR(ME)R, therefore, require the establishment of local DRLs by each hospital to act as an alternative guideline for safe radiation use. The aim of our audit was to establish local DRLs based on our experience operating with the use of the mini C-arm over the last 7 years. Methods: This retrospective audit evaluates the end dose–area product (DAP) recorded for common trauma and orthopaedic procedures using the mini C-arm in a busy district general hospital. We present the quartile data and have set the cut-off point as the third quartile for formulating the local DRLs, consistent with the methodology for the conventional fluoroscope. Results: For our data set (n = 1664), the third quartile DAP values were lowest for surgeries to the forearm (5.38 cGycm2), hand (7.62 cGycm2), and foot/ankle (8.56 cGycm2), and highest for wrist (10.64 cGycm2) and elbow (14.61 cGycm2) procedures. Advances in knowledge: To our knowledge, this is the largest data set used to establish local DRLs. Other centres may find our guidelines useful whilst they establish their own local DRLs.Keywords
This publication has 12 references indexed in Scilit:
- Intraoperative radiation safety in orthopaedics: a review of the ALARA (As low as reasonably achievable) principlePatient Safety in Surgery, 2016
- Defining reference levels for intra-operative radiation exposure in orthopaedic trauma: A retrospective multicentre studyInjury, 2015
- Radiation safety knowledge and practices among Irish orthopaedic traineesIrish Journal of Medical Science (1971 -), 2014
- Use of the mini C-arm for wrist fractures--establishing a diagnostic reference levelRadiation Protection Dosimetry, 2007
- Exposure to Direct and Scatter Radiation with Use of Mini-C-Arm FluoroscopyJournal of Bone and Joint Surgery, 2007
- Relationship Between Fluoroscopic Time, Dose–Area Product, Body Weight, and Maximum Radiation Skin Dose in Cardiac Interventional ProceduresAmerican Journal of Roentgenology, 2006
- Fluroscopy in paediatric fractures—setting a local diagnostic reference levelRadiation Protection Dosimetry, 2006
- Radiation Exposure in Hand Surgery: Mini Versus Standard C-ArmThe Journal of Hand Surgery, 2005
- Radiation Exposure with Use of the Mini-C-Arm for Routine Orthopaedic Imaging ProceduresJournal of Bone and Joint Surgery, 2005
- Dose area product measurement in orthopaedic trauma: An attempt at establishing a local diagnostic reference levelRadiography, 2004