Deep learning for the detection of moyamoya angiopathy using T2-weighted images: a multicenter study
Authors:
Open Access
- 1 February 2025
- journal article
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (2) , 1346-1357
Abstract
Background: Moyamoya angiopathy (MMA) can be potentially missed in the initial magnetic resonance (MR) examination without MR angiography (MRA). The aim of this study was to develop an optimal deep learning model based on T2-weighted imaging (T2WI) for MMA detection. Methods: This retrospective multicenter study included MMA patients, control group patients with normal MRA and patients with cerebrovascular disease except MMA from seven hospitals (site 1 to site 7). Five models, namely shallow convolutional neural network (SCNN), LeNet-5 Convolutional Neural Network (LeNet), Visual Geometry Group Network (VGG), Residual Neural Network (ResNet) and Dense Convolutional Network (DenseNet), were used for training and validation. The model training and internal validation were performed with data from sites 1–4. Data from sites 5–7 were used for independent external validation, and the optimal model was selected according to the results of accuracy. Chi-squared test was used to further verify the influence of different MR manufacturers, field strength, age at the MR examination and MRA score on the optimal model. Results: A total of 1,038 MMA patients, 1,211 normal MRA and 271 patients with cerebrovascular disease except MMA were included. DenseNet showed the highest accuracy (0.859, 95% CI: 0.833, 0.884) in the independent external validation, which was not significantly different from that of VGG (0.834, 95% CI: 0.807, 0.861) and ResNet (0.855, 95% CI: 0.829, 0.880) but was significantly higher than that of SCNN (0.631, 95% CI: 0.595, 0.665; P2=6.559, P=0.01). The accuracy of MMA with MRA who scored more than 5 was higher than that scoring ≤5 (≤5 vs. 6–10: χ2=10.734, P=0.001; ≤5 vs. ≥11: χ2=10.369, P=0.001). Conclusions: DenseNet based on T2WI can be used to screen MMA, outperforming SCNN, LeNet, VGG and ResNet. The MRA score of MMA affected the DenseNet accuracy.Keywords
This publication has 28 references indexed in Scilit:
- Deep Learning-Based Approach for the Diagnosis of Moyamoya DiseaseJournal of Stroke and Cerebrovascular Diseases, 2020
- Machine learning for detecting moyamoya disease in plain skull radiography using a convolutional neural networkEBioMedicine, 2019
- Deep Learning for MR Angiography: Automated Detection of Cerebral AneurysmsRadiology, 2019
- Progress in moyamoya diseaseNeurosurgical Review, 2018
- French clinical practice guidelines for Moyamoya angiopathyRevue Neurologique, 2018
- Meandering flow void around the splenium in moyamoya diseaseNeurological Research, 2017
- Diagnosis of Moyamoya Disease on Magnetic Resonance Imaging: Are Flow Voids in the Basal Ganglia an Essential Criterion for Definitive Diagnosis?Journal of Stroke and Cerebrovascular Diseases, 2013
- Diagnosis of moyamoya disease using 3-T MRI and MRA: value of cisternal moyamoya vesselsNeuroradiology, 2012
- Moyamoya disease: current concepts and future perspectivesThe Lancet Neurology, 2008
- Novel Magnetic Resonance Angiography Stage Grading for Moyamoya DiseaseCerebrovascular Diseases, 2005