Characterization of sodium removal to ultrafiltration volume in a peritoneal dialysis outpatient cohort
Open Access
- 6 April 2020
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Kidney Journal
- Vol. 14 (3) , 917-924
Abstract
Background: Failure to control volume is the second most common cause of peritoneal dialysis (PD) technique failure. Sodium is primarily removed by convection, but according to the three-pore model, water and sodium movements are not necessarily concordant. We wished to determine factors increasing sodium to water clearance in clinical practice.Methods: We reviewed 24-h peritoneal dialytic sodium removal (DSR) and ultrafiltration (UF) volume in consecutive PD patients attending for routine assessment of peritoneal membrane function and adequacy testing. We used a regression model with the DSR/UF ratio as the dependent variable. A second model with DSR as the dependent variable and interaction testing for UF was used as sensitivity analysis.Results: We included 718 adult PD patients. Mean values were 51.8 ± 64.6 mmol/day and 512 ± 517 mL/day for DSR and UF, respectively. In multivariable analysis, DSR/UF ratio was positively associated with transport type (fast versus slow, P < 0.001), serum sodium (P < 0.001) and diabetes (P = 0.026), and negatively associated with PD mode [automated PD versus continuous ambulatory PD (CAPD), P < 0.001] and the use of 2.27% glucose dialysate (P < 0.001). Sensitivity analysis showed positive interaction with UF for transport type (P < 0.001) and serum sodium (P = 0.032) and negative interaction for PD mode (P < 0.001) and cycles number (P < 0.001).Conclusions: CAPD, fast transport and high serum sodium allow relatively more sodium to be removed compared with water. Icodextrin has no effect on sodium removal once confounders have been accounted for. Although widely used in the assessment of PD patients, UF should not be considered as a surrogate for DSR in clinical practice.Keywords
This publication has 35 references indexed in Scilit:
- Fluid State and Blood Pressure ControlASAIO Journal, 2012
- Fluid Status in Peritoneal Dialysis Patients: The European Body Composition Monitoring (EuroBCM) Study CohortPLOS ONE, 2011
- The Impact of Strict Volume Control Strategy on Patient Survival and Technique Failure in Peritoneal Dialysis PatientsBlood Purification, 2011
- Correction of Serum Sodium for Glucose Concentration in Hemodialysis Patients With Poor Glucose ControlDiabetes Care, 2010
- Comparison of Volume Overload with Cycler-Assisted versus Continuous Ambulatory Peritoneal DialysisClinical Journal of the American Society of Nephrology, 2009
- Clinical effects of icodextrin in peritoneal dialysisClinical Kidney Journal, 2008
- Compared time profiles of ultrafiltration, sodium removal, and renal function in incident CAPD and automated peritoneal dialysis patientsAmerican Journal of Kidney Diseases, 2004
- Survival of Functionally Anuric Patients on Automated Peritoneal DialysisJournal of the American Society of Nephrology, 2003
- Effect of Kt/V on survival and clinical outcome in CAPD patients in a randomized prospective studyKidney International, 2003
- Peritoneal Sodium Mass Removal in Continuous Ambulatory Peritoneal Dialysis and Automated Peritoneal Dialysis: Influence on Blood Pressure ControlAmerican Journal of Nephrology, 2001