Vapor Intrusion in Homes over Gasoline‐Contaminated Ground Water in Stafford, New Jersey
Authors:
- Paul F. SandersPSPaul F. Sanders
- Ian HersIHIan Hers
- 13 February 2006
- journal article
- Published by Wiley in Groundwater Monitoring & Remediation
- Vol. 26 (1) , 63-72
Abstract
The potential for chemical vapor intrusion from contaminated ground water to the interior of homes was investigated at a site with a leaking underground gasoline storage tank in Stafford Township, New Jersey. This location exhibited conditions favorable to vapor intrusion, with sand soil and a water table depth of 3.3 m. Concentrations of volatile organic chemicals in the ground water were as high as 82 mg/L for total benzene, toluene, ethylbenzene, and xylene (BTEX) and up to 590 mg/L for methyl‐t‐butyl ether (MTBE). Soil vapor samples at multiple depths were taken adjacent to several homes. Inside the homes, air samples were taken on the main floor, in the basement, and under the foundation slab. Despite high ground water concentrations, only one home had measurable impacts to indoor air quality attributable to some of the ground water contaminants. In this house, the BTEX chemicals were not detected in the basement, indicating a lack of indoor air impacts from the ground water for these chemicals. Oxygen measurements suggested that degradation attenuated these chemicals as they diffused through the vadose zone. However, MTBE, 2,2,4‐trimethylpentane (isooctane), and cyclohexane were found in the indoor air. The first two of these chemicals served as gasoline‐specific tracers and indicated that vapor intrusion was occurring. Attenuation factors (the ratio of the indoor air concentration to a source soil vapor concentration) for the BTEX chemicals between the ground water and the indoor air were −5, and for MTBE was 1.2 × 10−5. Attenuation factors between the deep‐soil vapor and the basement air were as follows: BTEX compounds, −5; MTBE, 2.2 × 10−5; 2,2,4‐trimethylpentane, 3.6 × 10−4; and cyclohexane, 1.2 × 10−4. Attenuation factors between the subslab vapor and the basement air were 7 to 8 × 10−3.Keywords
This publication has 16 references indexed in Scilit:
- Evaluation of the Johnson and Ettinger Model for Prediction of Indoor Air QualityGroundwater Monitoring & Remediation, 2003
- An Evaluation of Vapor Intrusion Into Buildings through a Study of Field DataSoil and Sediment Contamination: An International Journal, 2002
- The Use of Indoor Air Measurements To Evaluate Intrusion of Subsurface VOC Vapors into BuildingsJournal of the Air & Waste Management Association, 2001
- VOC concentrations measured in personal samples and residential indoor, outdoor and workplace microenvironments in EXPOLIS-Helsinki, FinlandAtmospheric Environment, 2001
- Evaluation of vadose zone biodegradation of BTX vapoursJournal of Contaminant Hydrology, 2000
- National Human Exposure Assessment Survey (NHEXAS): distributions and associations of lead, arsenic, and volatile organic compounds in EPA Region 5Journal of Exposure Science & Environmental Epidemiology, 1999
- Quantification of aerobic biodegradation and volatilization rates of gasoline hydrocarbons near the water table under natural attenuation conditionsWater Resources Research, 1999
- Concentrations of Volatile Organic Compounds in Indoor Air - A ReviewIndoor Air, 1994
- Transport of subsurface contaminants into buildingsEnvironmental Science & Technology, 1992
- Heuristic model for predicting the intrusion rate of contaminant vapors into buildingsEnvironmental Science & Technology, 1991