Results of “elephant trunk” total aortic arch replacement using a multi-branched, collared graft prosthesis
- 10 December 2014
- journal article
- Published by Springer Nature in Heart and Vessels
- Vol. 31 (3) , 390-396
Abstract
We report on our experience with a simplified elephant trunk (ET) procedure with a multi-branched prosthesis (Vascutek® Siena™ Collared Graft). It consists of a proximal portion (20 cm) with prefabricated side branches, a collar and a distal portion (30 cm). The collar, which can be trimmed into any desired diameter, constitutes the suture portion to the descending aorta. Radiopaque markers in the distal portion indicate the landing zone. Between January 2011 and June 2013, 20 consecutive patients (10 women; mean age, 66 ± 9.3 years) underwent ET procedure, including 6 re-do cases. Underlying aortic diseases were acute dissection (n = 6), chronic dissection (n = 4), aneurysm (n = 8) and PAU (n = 2). Mean preoperative diameter of the descending aorta was 49.1 ± 12.9 mm (range 74.7–29.7 mm). Concomitant procedures included ascending aortic replacement in 16 patients; root replacement in 2; AVR in 2, CABG in 3 and mitral repair in 1 patient. CPB time was 263 ± 94 min; mean duration of ACP was 65 ± 14 min. Two patients died on POD 8 and 78, respectively. Major adverse events included stroke (n = 1), resternotomy for bleeding (n = 2), renal failure requiring temporary dialysis (n = 1) and recurrent nerve paresis (n = 2). After a mean follow-up of 10 ± 8 months, all discharged patients were alive. Seven patients underwent stent-graft implantation of the descending aorta and one patient underwent open descending aortic replacement. The last generation of multi-branched arch prosthesis and especially the Vascutek® Siena™ Collared Graft make ET procedure a reasonable treatment option even in patients with acute aortic dissection.Keywords
This publication has 28 references indexed in Scilit:
- Elephant trunk procedure 27 years after Borst: what remains and what is new?European Journal of Cardio-Thoracic Surgery, 2011
- Open chest management after cardiac operations: outcome and timing of delayed sternal closureEuropean Journal of Cardio-Thoracic Surgery, 2011
- Tight Heart Rate Control Reduces Secondary Adverse Events in Patients With Type B Acute Aortic DissectionCirculation, 2008
- Angiotensin II Blockade and Aortic-Root Dilation in Marfan's SyndromeNew England Journal of Medicine, 2008
- Losartan, an AT1 Antagonist, Prevents Aortic Aneurysm in a Mouse Model of Marfan SyndromeScience, 2006
- Selective Cerebral Perfusion Via Right Axillary Artery Direct Cannulation for Aortic Arch SurgeryThe Thoracic and Cardiovascular Surgeon, 2005
- Near-infrared spectroscopy for monitoring cerebral ischemia during selective cerebral perfusionEuropean Journal of Cardio-Thoracic Surgery, 2004
- The “elephant trunk” technique made easierThe Annals of Thoracic Surgery, 2004
- Rationale and Technique for Replacement of the Ascending Aorta, Arch, and Distal Aorta Using a Modified Elephant Trunk ProcedureJournal of Cardiac Surgery, 1992
- Extensive Aortic Replacement using “Elephant Trunk” ProsthesisThe Thoracic and Cardiovascular Surgeon, 1983