Study on the temperature modified method for monitoring gas concentrations with tunable diode laser absorption spectroscopy
Authors:
- Zhang Zhi-RongZZZhang Zhi-Rong
- Wu BianWBWu Bian
- Xia HuaXHXia Hua
- Pang TaoPTPang Tao
- Wang Gao-XuanWGWang Gao-Xuan
- Sun Peng-ShuaiSPSun Peng-Shuai
- Dong Feng-ZhongDFDong Feng-Zhong
- Wang YuWYWang Yu
- 1 January 2013
- journal article
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 62 (23) , 234204
Abstract
Tunable diode laser absorption spectroscopy (TDLAS) is often used to detect gas concentrations in many fields. But because of the variation of ambient temperature, the measured harmonic signal amplitudes are affected and may lead to the monitoring errors. The impact of temperature on the measurement as well as the temperature compensation method is emphasized. So in order to modify the inversion results and adapt industrial measurement, combustion diagnostics, the numerical fitting empirical modified equation and theoretical modified equation from HITRAN database are discussed and compared in this paper. In experiment, the 21% oxygen as the safety monitoring gas and absorption wavelength at 760.77 nm are employed. Meanwhile, the first harmonic signals are also used to decrease the laser intensity fluctuations. We thus obtained the unmodified and modified results with the tube furnace in the temperature range 300–900 K (interval 50 K). Experimental results show that these two modified methods have some effective influence on the temperature changes and can be applied to gas monitoring correction to improve the accuracy and feasibility of the TDLAS technology. In addition, the methods also provide evidence for the real-time gas monitoring in the application of combustion diagnosis.Keywords
This publication has 13 references indexed in Scilit:
- Calibration-free wavelength modulation spectroscopy for gas concentration measurements under low-absorbance conditionsChinese Physics B, 2012
- On the methodology of measuring high-speed flows using tunable diode laser absorption spectroscopyActa Physica Sinica, 2012
- On-line Monitoring of Industrial Toxic Gases with a Digital-Control ModuleActa Optica Sinica, 2011
- Measurements of the temperature and water vapor concentration in a hot zone by tunable diode laser absorption spectrometryApplied Physics B, 2010
- The HITRAN 2008 molecular spectroscopic databaseJournal of Quantitative Spectroscopy and Radiative Transfer, 2009
- Near-infrared diode laser absorption sensor for rapid measurements of temperature and water vapor in a shock tubeApplied Physics B, 2007
- The tunable diode laser absorption spectroscoty for measurement of NH3 with particlesActa Physica Sinica, 2007
- Absorption measurements of ambient methane with tunable diode laserActa Physica Sinica, 2005
- Calculation of the Ratio Between the Second and First Harmonic Signals in Wavelength-Modulation Spectroscopy for Absorption MeasurementOptical Review, 2003
- TRISTAR - a tracer in situ TDLAS for atmospheric researchApplied Physics B, 1998