Outcomes of toric intraocular lens realignment surgery done using slit-lamp method and wavefront aberrometry method
Authors:
Open Access
- 1 August 2023
- journal article
- research article
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 71 (8) , 2978-2983
Abstract
Purpose: To compare the slit-lamp method and wavefront aberrometry method based on outcomes of toric realignment surgeries. Settings: Tertiary care ophthalmic hospital. Design: Retrospective study. Methods: This study included all eyes undergoing toric intraocular lens (TIOL) realignment surgery between January 2019 and December 2021 for which TIOL axis assessment by slit-lamp method and wavefront aberrometry method was available. Data were retrieved from electronic medical records, and we documented demographics, uncorrected visual acuity (UCVA), subjective refraction, and TIOL axis by slit-lamp and wavefront aberrometry methods on postoperative day 1 and day 14. In patients with misalignment, TIOL was realigned to the original position in group 1 (27 patients) and to an axis based on calculations provided by wavefront aberrometer in group 2 (25 patients). Post-realignment surgery, UCVA, subjective refraction, and TIOL axis by slit-lamp and wavefront aberrometry methods were assessed and analyzed. Results: We analyzed 52 eyes and found that the mean preoperative misalignment with the slit-lamp method (44.9° ±20.0°) and wavefront aberrometry (47.1° ±19.5°) was similar. The corresponding degrees of misalignment post-TIOL repositioning surgeries were 5.2° ±5.2° (slit-lamp method) and 4.7° ±5.1° (wavefront aberrometry) (P = 0.615). Both groups showed significant improvement in median log of minimum angle of resolution (logMAR) UCVA and reduction in median refractive cylinder. Conclusions: Slit-lamp method is as good as wavefront aberrometer method to assess TIOL axis. Toric realignment surgery is found to be safe, and realigning TIOL based on either slit-lamp method or wavefront aberrometer method equally improved UCVA and decreased residual refractive cylinder.Keywords
This publication has 21 references indexed in Scilit:
- Rotational performance and corneal astigmatism correction during cataract surgery: Aspheric toric intraocular lens versus aspheric nontoric intraocular lens with opposite clear corneal incisionJournal of Cataract & Refractive Surgery, 2014
- Simple and accurate alignment of toric intraocular lenses and evaluation of their rotation errors using anterior segment optical coherence tomographyJapanese Journal of Ophthalmology, 2011
- Residual astigmatism produced by toric intraocular lens rotationJournal of Cataract & Refractive Surgery, 2011
- Clinical and experimental validation of a slit lamp modification to measure toric lens positionContact Lens and Anterior Eye, 2011
- The AcrySof Toric Intraocular Lens in Subjects with Cataracts and Corneal AstigmatismOphthalmology, 2010
- Objective analysis of toric intraocular lens rotation and centrationJournal of Cataract & Refractive Surgery, 2010
- Assessment of toric intraocular lens alignment by a refractive power/corneal analyzer system and slitlamp observationJournal of Cataract & Refractive Surgery, 2010
- Software-based assessment of postoperative rotation of toric intraocular lensJournal of Cataract & Refractive Surgery, 2009
- Rotational stability of a single-piece hydrophobic acrylic intraocular lens: New method for high-precision rotation controlJournal of Cataract & Refractive Surgery, 2007
- Evaluating the eye's rotational stability during standard photographyJournal of Cataract & Refractive Surgery, 2005