Mobile phase additives for enhancing the chromatographic performance of astaxanthin on nonendcapped polymeric C30‐bonded stationary phases
- 23 December 2008
- journal article
- research article
- Published by Wiley in Journal of Separation Science
- Vol. 32 (1) , 34-43
Abstract
Astaxanthin shows peak deformation and reduced peak area response when eluted with methanol and methyl tert‐butyl ether on nonendcapped polymeric C30‐bonded HPLC phases. The present study tested different column manufacturers, column batches, and ten mobile phase additives including acids, bases, buffers, complexing and antioxidant agents for improvement of peak shape and peak area response. Concerning chromatographic benefits and feasibility, ammonium acetate was found to be the best additive followed by triethylamine for all columns tested. Variation of the mobile phase pH equivalent and the column temperature showed no synergistic effects on peak shape and peak area response. Results indicate that peak tailing and variation of peak area response are due to different on‐column effects. Possible mechanisms of the observed phenomenon will be discussed.Keywords
This publication has 51 references indexed in Scilit:
- A small-scale method for quantitation of carotenoids in bacteria and yeastsJournal of Microbiological Methods, 2007
- Effects of Mobile Phase Ratios on the Separation of Plant Carotenoids by HPLC with a C30 ColumnChromatographia, 2006
- Rancidity development during the chilled storage of farmed Coho salmon ( Oncorhynchus kisutch )European Journal of Lipid Science and Technology, 2005
- Simultaneous HPLC determination of carotenoids used as food coloring additives: applicability of accelerated solvent extractionFood Chemistry, 2004
- Effects of astaxanthin-rich algal meal (Haematococcus pluvalis) on growth performance, caecal campylobacter and clostridial counts and tissue astaxanthin concentration of broiler chickensAnimal Feed Science and Technology, 2003
- Application of high‐performance liquid chromatography with photodiode array detection to the metabolic profiling of plant isoprenoidsThe Plant Journal, 2000
- Application of high-performance liquid chromatography with photodiode array detection to the metabolic profiling of plant isoprenoidsThe Plant Journal, 2000
- HPLC Separation of Geometric Carotene Isomers Using a Calcium Hydroxide Stationary PhaseJournal of Agricultural and Food Chemistry, 1995
- Resolution and Quantitation of the Predominant Geometric .beta.-Carotene Isomers Present in Human Serum Using Normal-Phase HPLCJournal of Agricultural and Food Chemistry, 1994
- SENSORY TESTING OF PEN‐REARED SALMON AND TROUTJournal of Food Science, 1976