A Hybrid Redox-Active Polymer Based on Bovine Serum Albumin, Ferrocene, Carboxylated Carbon Nanotubes, and Glucose Oxidase
- 3 September 2020
- journal article
- research article
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 75 (9) , 1189-1200
Abstract
We used conducting redox-active polymers based on chitosan and bovine serum albumin (BSA), covalently bound to mediators ferrocene or Neutral Red, or thionine, modified by carbon nanotubes, as a base of an amperometric biosensor for determining glucose. The structure of the obtained polymers was studied by IR spectroscopy and scanning electron microscopy. Their electrochemical characteristics were studied by cyclic voltammetry. The redox-active polymer based on BSA covalently bound to ferrocene and modified by carboxylated carbon nanotubes demonstrated the most promising characteristics. The biosensor based on the selected hybrid polymer is characterized by high sensitivity, a lower limit of determined concentrations of 0.05 mM, and a high correlation coefficient (R = 0.9919) with the results of determination of glucose in human blood by an alternative method.Keywords
This publication has 27 references indexed in Scilit:
- Direct electron transfer glucose biosensor based on glucose oxidase self-assembled on electrochemically reduced carboxyl grapheneBiosensors and Bioelectronics, 2013
- Chitosan–ferrocene film as a platform for flow injection analysis applications of glucose oxidase and Gluconobacter oxydans biosensorsColloids and Surfaces B: Biointerfaces, 2012
- Electrochemistry, AFM, and PM‐IRRA Spectroscopy of Immobilized Hydrogenase: Role of a Hydrophobic Helix in Enzyme Orientation for Efficient H2 OxidationAngewandte Chemie International Edition, 2011
- Ferrocene-modified multiwalled carbon nanotubes as building block for construction of reagentless enzyme-based biosensorsSensors and Actuators B: Chemical, 2008
- Ferrocene Branched Chitosan for the Construction of a Reagentless Amperometric Hydrogen Peroxide BiosensorMacromolecular Bioscience, 2007
- Synthesis of Ferrocene‐Branched Chitosan Derivatives: Redox Polysaccharides and their Application to Reagentless Enzyme‐Based BiosensorsMacromolecular Rapid Communications, 2007
- A conductive ormosil encapsulated with ferrocene conjugate and multiwall carbon nanotubes for biosensing applicationBiomaterials, 2006
- Organically Modified Sol‐Gel/Chitosan Composite Based Glucose BiosensorElectroanalysis, 2003
- General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systemsJournal of Electroanalytical Chemistry and Interfacial Electrochemistry, 1979
- Theory and Application of Cyclic Voltammetry for Measurement of Electrode Reaction Kinetics.Analytical Chemistry, 1965