A three-dimensional finite element analysis of a passive and friction fit implant abutment interface and the influence of occlusal table dimension on the stress distribution pattern on the implant and surrounding bone
Authors:
Open Access
- 1 January 2015
- journal article
- research article
- Published by Medknow in The Journal of Indian Prosthodontic Society
- Vol. 15 (3) , 229-36
Abstract
Aims: The aim of the study was to evaluate the stress distribution pattern in the implant and the surrounding bone for a passive and a friction fit implant abutment interface and to analyze the influence of occlusal table dimension on the stress generated. Materials and Methods : CAD models of two different types of implant abutment connections, the passive fit or the slip-fit represented by the Nobel Replace Tri-lobe connection and the friction fit or active fit represented by the Nobel active conical connection were made. The stress distribution pattern was studied at different occlusal dimension. Six models were constructed in PRO-ENGINEER 05 of the two implant abutment connection for three different occlusal dimensions each. The implant and abutment complex was placed in cortical and cancellous bone modeled using a computed tomography scan. This complex was subjected to a force of 100 N in the axial and oblique direction. The amount of stress and the pattern of stress generated were recorded on a color scale using ANSYS 13 software. Results : The results showed that overall maximum Von Misses stress on the bone is significantly less for friction fit than the passive fit in any loading conditions stresses on the implant were significantly higher for the friction fit than the passive fit. The narrow occlusal table models generated the least amount of stress on the implant abutment interface. Conclusion : It can thus be concluded that the conical connection distributes more stress to the implant body and dissipates less stress to the surrounding bone. A narrow occlusal table considerably reduces the occlusal overload.Keywords
This publication has 38 references indexed in Scilit:
- Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysisJournal of Applied Oral Science, 2011
- Implant-prosthetic rehabilitation of the edentulous maxilla and mandible with immediately loaded implants: preliminary data from a retrospective study, considering time of implantation.2011
- Effects of repeated manual disassembly and reassembly on the positional stability of various implant-abutment complexes: an experimental study.2010
- Fracture resistance of the implant-abutment connection in implants with internal hex and internal conical connections under oblique compressive loading: an in vitro study.2009
- A Finite Element Analysis of Two Different Dental Implants: Stress Distribution in the Prosthesis, Abutment, Implant, and Supporting BoneJournal of Oral Implantology, 2008
- A conical implant–abutment interface at the level of the marginal bone improves the distribution of stresses in the supporting boneClinical Oral Implants Research, 2003
- Timing of loading and effect of micromotion on bone-dental implant interface: Review of experimental literatureJournal of Biomedical Materials Research, 1998
- Design, maintenance and biomechanical considerations in implant placement.1997
- Modeling the biomechanics of the mandible: A three-dimensional finite element studyJournal of Biomechanics, 1992
- Dental implant abutment resembling the two-phase tooth mobilityJournal of Biomechanics, 1990