Helical toroid phantom for 3D flow imaging investigations
Authors:
Open Access
- 11 February 2021
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (4) , 045029
Abstract
The medical physics community has hitherto lacked an effective calibration phantom to holistically evaluate the performance of three-dimensional (3D) flow imaging techniques. Here, we present the design of a new omnidirectional, three-component (3-C) flow phantom whose lumen is consisted of a helical toroid structure (4 mm lumen diameter; helically winded for 5 revolutions over a torus with 10 mm radius; 5 mm helix radius). This phantom’s intraluminal flow trajectory embraces all combinations of x , y , and z directional components, as confirmed using computational fluid dynamics (CFD) simulations. The phantom was physically fabricated via lost-core casting with polyvinyl alcohol cryogel (PVA) as the tissue mimic. 3D ultrasound confirmed that the phantom lumen expectedly resembled a helical toroid geometry. Pulsed Doppler measurements showed that the phantom, when operating under steady flow conditions (3 ml s −1 flow rate), yielded flow velocity magnitudes that agreed well with those derived from CFD at both the inner torus (−47.6 ± 5.7 versus −52.0 ± 2.2 cm s −1 ; mean ± 1 S.D.) and the outer torus (49.5 ± 4.2 versus 48.0 ± 1.7 cm s −1 ). Additionally, 3-C velocity vectors acquired from multi-angle pulsed Doppler showed good agreement with CFD-derived velocity vectors (<7% and 10° difference in magnitude and flow angle, respectively). Ultrasound color flow imaging further revealed that the phantom’s axial flow pattern was aligned with the CFD-derived flow profile. Overall, the helical toroid phantom has strong potential as an investigative tool in 3D flow imaging innovation endeavors, such as the development of flow vector estimators and visualization algorithms.Keywords
Funding Information
- Canadian Institutes of Health Research (PJT-153240)
- Natural Sciences and Engineering Research Council of Canada (CREATE-528202-2019)
- Canada Foundation for Innovation (36138)
- Ontario Early Researcher Award (ER16-12-186)
This publication has 47 references indexed in Scilit:
- Phantoms for Ultrasound Experimentation and Quality Control2013
- Multi-line transmission in 3-D with reduced crosstalk artifacts: a proof of concept studyIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2013
- Design of Anthropomorphic Flow Phantoms Based on Rapid Prototyping of Compliant Vessel GeometriesUltrasound in Medicine & Biology, 2013
- Particle Image Velocimetry for Complex and Turbulent FlowsAnnual Review of Fluid Mechanics, 2013
- Development of a Range of Anatomically Realistic Renal Artery Flow PhantomsUltrasound in Medicine & Biology, 2010
- 3‐D visualization and animation technologies in anatomical imagingJournal of Anatomy, 2010
- Simulation and Validation of Arterial Ultrasound Imaging and Blood FlowUltrasound in Medicine & Biology, 2008
- Anatomical flow phantoms of the nonplanar carotid bifurcation, Part II: Experimental validation with Doppler ultrasoundUltrasound in Medicine & Biology, 2007
- Anatomical flow phantoms of the nonplanar carotid bifurcation, Part I: Computer-aided design and fabricationUltrasound in Medicine & Biology, 2007
- Lumen diameter of normal human coronary arteries. Influence of age, sex, anatomic variation, and left ventricular hypertrophy or dilation.Circulation, 1992