Influence of the winding design of wind turbine transformers for resonant overvoltage vulnerability
Authors:
- 9 April 2015
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 22 (2) , 1250-1257
Abstract
Switching transients and earth faults may lead to resonant overvoltages at wind turbine transformer terminals as well as inside High Voltage (HV) and Low Voltage (LV) windings. The winding design in a transformer could strongly influence the internal voltage distribution as function of frequency, and this has a great impact on risk of insulation failure. In this paper, resonant overvoltages in three winding designs; layer, disc and pancake, are investigated and analyzed for the application in offshore wind farm. To achieve this, a prototype 500 kVA transformer with the three winding types on the HV side and taps for voltage measurements is designed and produced. The measurements show that a HV winding of layer type gives the highest transferred voltage to the LV terminal and that this happens at 1.6 MHz which could be excited for close-up earth faults. Although disc winding seems the least vulnerable when measuring the transferred voltage to the LV terminal, it has higher potential of internal resonances in the HV winding compared to the two other types both voltage-to-ground and voltage drops. Pancake and layer windings have less vulnerability in the case of internal resonances. Pancake windings have modular design characteristic. This advantage eases the repair for offshore wind applications.Keywords
This publication has 17 references indexed in Scilit:
- Frequency domain investigation of switching transients in Offshore Wind Farms2011
- Multivariate Analysis of Transformer Resonant Overvoltages in Power StationsIEEE Transactions on Power Delivery, 2011
- Internal Winding Failure Due to Resonance Overvoltage in Distribution Transformer Caused by Winter LightningIEEE Transactions on Power Delivery, 2006
- Computation of very fast transient overvoltages in transformer windingsIEEE Transactions on Power Delivery, 2003
- Experimental and numerical analysis of fast transient phenomena in distribution transformers2002
- Failure mechanism of the interturn insulation of low voltage electric machines fed by pulse-controlled invertersIEEE Electrical Insulation Magazine, 1996
- Analysis of internal winding stresses in EHV generator step-up transformer failuresIEEE Transactions on Power Delivery, 1996
- Dielectric strength of transformer insulation against oscillatory impulse voltagesElectrical Engineering in Japan, 1984
- Transformer Response to System Switching VoltagesIEEE Transactions on Power Apparatus and Systems, 1982
- Resonant Overvoltages in EHV Transformers-Modeling and ApplicationIEEE Transactions on Power Apparatus and Systems, 1981