Direct imaging of single cells and tissue at sub‐cellular spatial resolution using transmission geometry MALDI MS
- 7 November 2012
- journal article
- research article
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 47 (11) , 1473-1481
Abstract
The need of cellular and sub‐cellular spatial resolution in laser desorption ionization (LDI)/matrix‐assisted LDI (MALDI) imaging mass spectrometry (IMS) necessitates micron and sub‐micron laser spot sizes at biologically relevant sensitivities, introducing significant challenges for MS technology. To this end, we have developed a transmission geometry vacuum ion source that allows the laser beam to irradiate the back side of the sample. This arrangement obviates the mechanical/ion optic complications in the source by completely separating the optical lens and ion optic structures. We have experimentally demonstrated the viability of transmission geometry MALDI MS for imaging biological tissues and cells with sub‐cellular spatial resolution. Furthermore, we demonstrate that in conjunction with new sample preparation protocols, the sensitivity of this instrument is sufficient to obtain molecular images at sub‐micron spatial resolution. Copyright © 2012 John Wiley & Sons, Ltd.Keywords
This publication has 38 references indexed in Scilit:
- Sublimation of New Matrix Candidates for High Spatial Resolution Imaging Mass Spectrometry of Lipids: Enhanced Information in Both Positive and Negative Polarities after 1,5-Diaminonapthalene DepositionAnalytical Chemistry, 2012
- Stretched Tissue Mounting for MALDI Mass Spectrometry ImagingAnalytical Chemistry, 2011
- Reagent Precoated Targets for Rapid In-Tissue Derivatization of the Anti-Tuberculosis Drug Isoniazid Followed by MALDI Imaging Mass SpectrometryJournal of the American Society for Mass Spectrometry, 2011
- Imaging mass spectrometry in transmission geometryRapid Communications in Mass Spectrometry, 2011
- Imaging of lipid species by MALDI mass spectrometryJournal of Lipid Research, 2009
- Sublimation as a method of matrix application for mass spectrometric imagingJournal of the American Society for Mass Spectrometry, 2007
- LIPID MAPS online tools for lipid researchNucleic Acids Research, 2007
- Adjustable Fragmentation in Laser Desorption/Ionization from Laser-Induced Silicon Microcolumn ArraysAnalytical Chemistry, 2006
- Matrix-assisted Laser Desorption/Ionization in Transmission Geometry: Instrumental Implementation and Mechanistic ImplicationsRapid Communications in Mass Spectrometry, 1996
- A RAPID METHOD OF TOTAL LIPID EXTRACTION AND PURIFICATIONCanadian Journal of Biochemistry and Physiology, 1959