An advanced scheme of compressed sensing of acceleration data for telemonintoring of human gait
Open Access
- 5 March 2016
- journal article
- research article
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 15 (1) , 1-15
Abstract
The compressed sensing (CS) of acceleration data has been drawing increasing attention in gait telemonitoring application. In such application, there still exist some challenging issues including high energy consumption of body-worn device for acceleration data acquisition and the poor reconstruction performance due to nonsparsity of acceleration data. Thus, the novel scheme of compressive sensing of acceleration data is needed urgently for solutions that are found to these issues. In our scheme, the sparse binary matrix is firstly designed as an optimal measurement matrix only containing a smallest number of nonzero entries. And then the block sparse Bayesian learning (BSBL) algorithm is introduced to reconstruct acceleration data with high fidelity by exploiting block sparsity. Finally, some commonly used gait classification models such as multilayer perceptron (MLP), support vector machine (SVM) and KStar are applied to further validate the feasibility of our scheme for gait telemonitoring application. The acceleration data were selected from open Human Activity Dataset of Southern California University (USC-HAD). The optimal sparse binary matrix (a smallest number of nonzero entries is 8) is as strong as the full optimal measurement matrix such as Gaussian random matrix. Moreover, BSBL algorithm significantly outperforms existing conventional CS reconstruction algorithms, and reaches the maximal signal-to-noise ratio value (70 dB). In comparison, MLP is best for gait classification, and it can classify upstairs and downstairs patterns with best accuracy of 95 % and seven gait patterns with maximal accuracy of 92 %, respectively. These results show that sparse binary matrix and BSBL algorithm are feasibly applied in compressive sensing of acceleration data to achieve the perfect compression and reconstruction performance, which has a great potential for gait telemonitoring application.Keywords
Funding Information
- the natural science fund project from Fujian Province (No.2013J01220)
This publication has 34 references indexed in Scilit:
- Feature Selection and Activity Recognition System Using a Single Triaxial AccelerometerIEEE Transactions on Biomedical Engineering, 2014
- An Energy Efficient Compressed Sensing Framework for the Compression of Electroencephalogram SignalsSensors, 2014
- Wireless sensor networks for rehabilitation applications: Challenges and opportunitiesJournal of Network and Computer Applications, 2013
- Acceleration-based gait test for healthy subjects: Reliability and reference dataGait & Posture, 2009
- Reliability and validity of an activity monitor (IDEEA) in the determination of temporal–spatial gait parameters in individuals with cerebral palsyGait & Posture, 2008
- A Fast Approach for Overcomplete Sparse Decomposition Based on Smoothed $\ell ^{0}$ NormIEEE Transactions on Signal Processing, 2008
- An Interior-Point Method for Large-Scale -Regularized Least SquaresIEEE Journal of Selected Topics in Signal Processing, 2007
- A Review of Approaches to Mobility Telemonitoring of the Elderly in Their Living EnvironmentAnnals of Biomedical Engineering, 2006
- Model Selection and Estimation in Regression with Grouped VariablesJournal of the Royal Statistical Society Series B: Statistical Methodology, 2005