Calibration of the Periotron 8000® and 6000® by polynomial regression
Authors:
- 1 February 1999
- journal article
- Published by Wiley in Journal of Periodontal Research
- Vol. 34 (2) , 79-86
Abstract
This paper reports the detailed calibration of the new Periotron 8000® with different fluids and uses the method of least squares to derive polynomial regression equations up to the 6th order, to investigate the most accurate descriptor of the resulting calibration lines. The use of a 4th order polynomial regression equation (recommended by the manufacturer) provided better coefficients of determination (R2: 0.999) and root mean square errors (RMSE = 1.6) than either linear regression (R2: 0.986, RMSE = 10.9) or quadratic models (R2: 0.998, RMSE = 3.2). Data derived using the manufacturer's MLCONVERT software program lacked accuracy and incurred large errors for volumes > 0.5 μl. Calibrations performed on one day could be used with accuracy to derive volumes >0.1 μl collected on subsequent days, when using the same machine (s.d. for residuals plot=2.49 Periotron units), but this was not the case for different machines (s.d. = 9.57 Periotron units). Varying serum protein concentration by up to 500% had a negligible effect on calculated volumes above 0.1 μl. We conclude that the Periotron 8000® is at least as reliable a machine as the Periotron 6000®, and that the calibration lines for both machines are best described using 4th order polynomial regression equations and “look‐up” tables, rather than quadratic (Periotron 6000®) or the manufacturer's software (Periotron 8000®). Serum seems to be an acceptable GCF substitute for calibrations, which can be performed 1 day, and used on subsequent days for a given machine and for volumes above 0.1 μl.Keywords
This publication has 10 references indexed in Scilit:
- Quadratic calibration curves for the Periotron 6000RJournal of Periodontal Research, 1996
- Determination of small sample volumes in the analysis of drugs at specific sites in the oral cavityJournal of Periodontal Research, 1995
- Calibration and reliability of the Periotron 6000 for individual gingival crevicular fluid samplesJournal of Periodontal Research, 1995
- Reliability of Crevicular Fluid Measurements Taken in the Presence of Supragingival PlaqueJournal of Periodontology, 1990
- Selection of a filter paper with optimum properties for the collection of gingival crevicular fluidJournal of Periodontal Research, 1988
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- The periotron gingival crevicular fluid meterJournal of Periodontal Research, 1986
- A comparison of 3 systems for quantifying gingival crevicular fluid with respect to linearity and the effects of qualitative differences in fluidsJournal of Clinical Periodontology, 1984
- Reliability of volume measurements with the new Periotron® 6000Journal of Periodontal Research, 1984
- Relative Error (Variability) Associated With an Improved Instrument for Measuring Gingival Crevicular FluidJournal of Periodontology, 1984