Real-time volumetric imaging system for CMUT arrays
- 1 October 2011
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10510117,p. 1064-1067
Abstract
We designed and implemented a flexible real-time volumetric ultrasound imaging system for capacitive micromachined ultrasonic transducer (CMUT) arrays, consisting of an ultrasound data acquisition system, an FPGA board, and a host PC. The system works with arbitrary-shaped CMUT arrays and non-standard beamforming methods, as well as with regular-shaped CMUT arrays and conventional beamforming methods. In this paper, we present the system design and real-time imaging results obtained using this system with a ring array, a rectangular array, and a linear array. In synthetic phased array (SPA) imaging with a 64-element ring array, we could display 3 image planes with a total of about 70,000 pixels in real time, at a frame rate of 9 frames per second (fps) which was limited by the computational load on the CPU required for synthetic beamforming. On the other hand, the frame rate in classic phased array (CPA) imaging is limited by the data transfer time. In CPA imaging with a 16×16-element rectangular array, a frame rate of 5.4 fps was achieved for 1,250 acquisitions per frame and a 2.5-cm imaging depth. The frame rate can be increased by reducing the number of pixels processed in SPA, or by reducing the number of beams received in CPA, at the expense of degraded image quality or reduced field of view.Keywords
This publication has 12 references indexed in Scilit:
- An integrated circuit with transmit beamforming flip-chip bonded to a 2-D CMUT array for 3-D ultrasound imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2009
- Forward-looking volumetric intracardiac imaging using a fully integrated CMUT ring array2009
- Forward-looking intracardiac ultrasound imaging using a 1-D CMUT array integrated with custom front-end electronicsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2008
- Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2008
- Low temperature fabrication of immersion capacitive micromachined ultrasonic transducers on silicon and dielectric substratesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2004
- Capacitive micromachined ultrasonic transducers: next-generation arrays for acoustic imaging?IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2002
- Sparse array imaging with spatially-encoded transmits2002
- Space–time encoding for high frame rate ultrasound imagingUltrasonics, 2002
- Synthetic aperture imaging with arrays of arbitrary shape. II. The annular arrayIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2002
- Annular array imaging with full-aperture resolutionThe Journal of the Acoustical Society of America, 1992