The impact of traditional and smart pump infusion technology on nurse medication administration performance in a simulated inpatient unit
Open Access
- 27 April 2010
- journal article
- research article
- Published by BMJ in BMJ Quality & Safety
- Vol. 19 (5) , 430-434
Abstract
Objective Assess the impact of infusion pump technologies (traditional pump vs smart pump vs smart pump with barcode) on nurses' ability to safely administer intravenous medications. Design Experimental study with a repeated measures design. Setting High-fidelity simulated inpatient unit. Results The nurses remedied 60% of “wrong drug” errors. This rate did not vary as a function of pump type. The nurses remedied “wrong patient” errors more often when using the barcode pump (88%) than when using the traditional pump (46%) or the smart pump (58%) (Cochran Q=14.36; pConclusions These findings indicate that soft (changeable) limits in smart infusion pumps had no significant effect in preventing dosing errors. Provided that smart pumps are programmed with hard (unchangeable) limits, they can prevent dosing errors, thereby increasing patient safety. Until barcode pumps are integrated with other systems within the medication administration process, their role in enhancing patient safety will be limited. Further improvements to pump technologies are needed to mitigate risks associated with intravenous infusions, particularly secondary infusions.Keywords
This publication has 22 references indexed in Scilit:
- ASHP national survey on informatics: Assessment of the adoption and use of pharmacy informatics in U.S. hospitals—2007American Journal of Health-System Pharmacy, 2008
- Smart infusion technology: a minimum safety standard for intensive care?British Journal of Nursing, 2008
- Time to Get Off this Pig's Back?Journal of Patient Safety, 2006
- Standard Drug Concentrations and Smart-Pump Technology Reduce Continuous-Medication-Infusion Errors in Pediatric PatientsPediatrics, 2005
- Variability in Intravenous Medication Practices: Implications for Medication SafetyThe Joint Commission Journal on Quality and Patient Safety, 2005
- Insights from the sharp end of intravenous medication errors: implications for infusion pump technologyQuality and Safety in Health Care, 2005
- Improving Recognition of Drug InteractionsMedical Care, 2002
- GPs' views on computerized drug interaction alerts: questionnaire surveyJournal of Clinical Pharmacy and Therapeutics, 2002
- Medication errors in a paediatric teaching hospital in the UK: five years operational experienceArchives of Disease in Childhood, 2000
- The Nature of Adverse Events in Hospitalized PatientsNew England Journal of Medicine, 1991